Editor's Choice


Beckhoff upgrade is music to Vienna State Opera’s ears

June 2022 Editor's Choice

The renowned Vienna State Opera in Austria is considered one of the world’s leading opera houses. There are around 300 performances with more than 60 different operas and ballets each season. This schedule is an enormous challenge for both the employees who work in shifts and for the stage technology, which must function smoothly.

To give visitors the best possible listening experience, the sound system has been upgraded using state-of-the-art audio technology and an entirely refurbished audio control system. The system was brought to life by Viennese company Salzgeber, a specialist in planning and implementing high-tech audio and video systems, working closely with Beckhoff Austria.

The system requirements for the sound technology were extensive: in addition to perfect acoustics, it needed to provide optimised diagnostics options plus energy metering with the ability to visualise the system, especially the amplifiers. “The sound system that had been in continuous use at the Vienna State Opera for over 20 years could no longer keep up with the sound standards set by modern systems. Our situation involves typical audio signals such as opera vocals, acoustic instruments, a choir, an organ and incidental music,” explains Athanasios Rovakis, who is in charge of sound and video systems at the venue.

The choice of speakers was primarily determined by artistic requirements, such as organically embedding vocal and instrumental soloists or a choir, depending on the production. The speakers also needed to produce a certain sense of direction and distance for the sounds, and a certain sound ‘character’. “Today’s systems, with their modellable coverage, can be used and tuned very differently than they were just a few years ago. This is particularly important in situations involving a lot of room acoustics, as is the case in this theatre,” says Rovakis.

“Due to its unique architecture, the Vienna State Opera house has very lively acoustics and there are sometimes long distances and different types of directivity to deal with. The auditory impression in the orchestra stalls is different from the one in the gallery, for example. Collectively, voices can be heard better further back in the ‘Stehparterre’, a standing section of the hall, while the upper tiers receive a more balanced sound. The auditorium can accommodate almost 2700 visitors, most of whom sit in the upper two tiers, so of course we have to take that into account when it comes to the sound system,” the head audio engineer explains.

After several years of careful planning, the rebuild of the entire audio system was completed in November 2020. Tino Pfeifer, senior project engineer at Salzgeber, was involved from the very beginning. He planned and developed the monitored power supply, the amplifier monitoring and the connection between the amplifiers and additional signals.

“I decided to go with an L-Acoustics speaker system – specifically, the ARCS W/F series sounded particularly good for the applications in this space. All the other integration steps then had to be based on the selected system, or be compatible with it,” reports Rovakis. The sound master wanted a diagnostic option based on collected and analysed audio and power amplifier data. Rovakis continues: “This is a function that we had previously found to be very time-consuming to implement in analog form, and which we definitely wanted to see brought up to date.

“With the variety of audio channels we have to manage here, it’s important that we can clearly see if a signal is actually getting to where it was intended for. We also have remote control abilities – for example, muting via physical pushbuttons, which are also integrated into the automation of the audio mixing console.” Other requirements were energy monitoring and fault diagnostics for the audio devices, as well as visualisation of the audio system.

The next step was to find a solution that combines these functions with the selected audio system. This is where Beckhoff came into play as a control equipment supplier. Since the audio devices from L-Acoustics communicate with the control system via an SNMP (Simple Network Management Protocol v1.0) interface, Christian Henke from Beckhoff Austria worked closely with Salzgeber to develop a matching communication function block for TwinCAT 3.1 software. “Our TCP/IP server (TF6310) makes it possible to control an unlimited number of devices and functions. This is a unique selling point in the industry. And the response times that we offer are even faster than what was required,” comments Michel Matuschke, manager for the entertainment industry at Beckhoff.

Energy metering for the audio system

Since the 1950s, the Vienna State Opera’s sound technology has been repeatedly added to and, in some cases, replaced. “This means that layer after layer was laid on top of each other, and that gave us a rather confusing system of cables and individual components to deal with in the sound control room,” explains Rovakis. “With the help of Tino Pfeifer from Salzgeber, we completely redesigned the sound control room in a highly modular way, which hopefully means that we won’t have to make any more fundamental changes to it in the next 25 years.”

The power distribution in the control room, the point from which all the audio and video equipment is controlled, now consists of only three cable types for incoming circuits, outgoing circuits and the network. “The Beckhoff C6015 ultra-compact industrial PC with an EK1100 EtherCAT coupler and matching bus terminals is used for power distribution; it switches the power supply on and off as needed, and performs diagnostics on the protective switches,” says Tino Pfeifer.

Instead of hard-wired devices, Salzgeber designed a flexible system consisting of eighteen 19-inch rack elements. Using the individual racks, all consumers and each outlet can now be assigned to groups, switched and have their energy status read. This configuration was created with the aim of flexibly switching interrelated functional units together independent of their location. The modular bus design even allows entire racks to be separated and moved out of the room for servicing.

“With such a vast number of performances and rehearsals to deal with, each with different technical requirements, this really helps us keep track of everything,” says Rovakis. “We have duplicates of every critical component in case something breaks. We analyse the three phases of the mains supply, which are equipped with their own residual-current device or circuit breaker. We can dynamically switch devices via six remotely controlled and monitored ports, which are in the form of socket arrays.”

All of the racks are based on the same structure, which includes a BK9100 Ethernet bus coupler with two KL3403 3-phase power measurement terminals, six current transformers, two KM2614 4-channel relay terminals with 16 A wired-to-break contacts, and a KL1809 for monitoring the ground fault circuit interrupter switches. In total, more than 100 switching channels are available with a wide range of monitoring options.

The power measurement terminal accurately displays the status of each load. Envelope curve analysis is used to monitor the current consumption of each outgoing circuit, with the resulting data stored for reference. The racks can be operated via two central keypads, as well as on the PC. “But we can also operate all the functions downstairs from the auditorium – all we need is a network connection,” adds Rovakis.

Visualisation displays the status of all power amplifiers

The visualisation software was implemented on the basis of the TwinCAT HMI server (TF2000) which runs on a C6515 control-cabinet industrial PC. The HMI used for displaying the status of all audio devices is made up of approximately 1000 PLC variables on one HMI page, with the variables updated every 50 ms. It includes various windows that show power distribution, status monitoring and audio signals.

“The development of the visualisation or field of view was one of the most important aspects as far as we were concerned, and one of the main reasons for choosing to work with Beckhoff,” states Rovakis. “Now we can use the monitor to track where things are happening. When you play an audio signal in a scenario where the speakers are far away, you receive a diffuse noise whose origin you can’t exactly determine when working at the mixer. This is where the 3D arrangement of speaker VU meters in the HMI comes in handy.”

The audio outputs can be muted individually or all together via physical buttons in the control room, via the audio consoles and via the HMI. The current operating status of the amplifiers is also illuminated in the control room. A pleasant indirect light is created via LED strips. Blue indicates that speakers are muted. Red and dimmed ambient lighting in the fully automated control room is an ‘on-air’ signal, which heightens the concentration of the operators.

“One major reason for choosing the Beckhoff control system was its openness and the long-term availability of the components. The bus terminals enable us to cover every function and we have even added value by implementing functions that we had not even considered before,” Rovakis concludes.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Flexible EtherCAT communication interface for DALI-2
Beckhoff Automation Fieldbus & Industrial Networking
The EL6821 EtherCAT Terminal from Beckhoff allows up to 64 DALI/DALI-2 slaves and 64 DALI-2 input devices to be connected. The TwinCAT 3 System Manager makes it easy to configure and parameterise DALI devices flexibly.

Read more...
EtherCAT-based control technology for building automation
Beckhoff Automation Fieldbus & Industrial Networking
Modern non-residential buildings place many high demands on building automation. This can be optimally implemented with EtherCAT-based control technology from Beckhoff, which provides an efficient central automation architecture thanks to ultra-fast data communication.

Read more...
PC-based control for university studies
Beckhoff Automation Fieldbus & Industrial Networking
The IDEA box developed at Heilbronn University of Applied Sciences is designed to introduce students to the topic of Industry 4.0 in a simple and practical way. At the core of the corresponding demo case is PC-based control from Beckhoff.

Read more...
Loop signature 22: How cyclical disturbances affect a control loop
Michael Brown Control Engineering Editor's Choice
When tuning noisy loops, we recommend in our courses that one should eliminate the noise by editing it out, so the tuning will be done only on the true process response, free of any noise. The controller is controlling the process, and is not controlling the noise.

Read more...
High-performance motion control for teabag packaging machine
Beckhoff Automation Editor's Choice
Teepak relies on PC-based control and drive technology from Beckhoff to set new benchmarks for speed and precision in its teabag packaging machines.

Read more...
VEGA takes the pressure out of water pressure measurement
VEGA Controls SA Editor's Choice
Water treatment systems in metropolitan areas require careful monitoring and management processes across widespread networks. However, process plants choosing VEGA for their process automation know that the company offers more than just precise and reliable pressure sensors and instrumentation.

Read more...
Advantages of wireless storage tank and container tank level monitoring
Turck Banner Southern Africa Editor's Choice
Implementing a tank monitoring system that utilises ultrasonic or radar sensors in a wireless network has many advantages.

Read more...
Bringing Industry 4.0 to a castings foundry for heavy industries
Editor's Choice
Moving to Industry 4.0 takes time and determination, especially for an established company in a heavy industry. Castings foundry, POK in Mexico has moved toward Industry 4.0 in a series of steps over several years, changing from manual to automated systems for more available, immediate and reliable data.

Read more...
SMOM – the future is here now
Iritron Editor's Choice IT in Manufacturing
In his presentation at the recent MESA Africa conference, Neels van der Walt, business development manager at Iritron, revealed the all-encompassing concept of smart mining operations management (SMOM), and why it is inextricably linked to the future of worldwide mining operations.

Read more...
Navigating disruption in manufacturing
Editor's Choice IT in Manufacturing
When considering IT in manufacturing, the underlying assumption is twofold: first, a wave of valuable maturing technologies can be harnessed to create new business value, and second, the environment in which these technologies will be applied will be relatively predictable, with change following a manageable, evolutionary path. However, recent disruptions have shattered these assumptions.

Read more...