Fieldbus & Industrial Networking


Full integration of Interbus in Profinet

June 2007 Fieldbus & Industrial Networking

Based on the Enhanced Real-Time Ethernet Controller (Ertec) 400 that was developed for Profinet-IRT, there are now two powerful Interbus proxies available from Phoenix Contact. They differ only in the construction of the Interbus master: The FL NP PND-4TX IB uses copper wiring for the Interbus system. The FL NP PND-4TX IB-LK employs fibre-optic cabling.

Interbus offers the full functional range of Generation 4. A proxy can address up to 8192 I/O signals in both input and output directions, for a maximum of up to 512 I/O modules. All Interbus diagnostic functions, right down to the individual circuit diagnostics, are mapped to Profinet mechanisms. 500-kilobaud and 2-megabaud systems can be connected. Profinet supports update rates right down to 1 ms. This allows the proxy to be employed when migrating applications to Profinet, making it possible to integrate anything from small Interbus segments to complete networks.

Both proxies combine the Interbus master with a four-port control cabinet switch on the basis of Ertec 400, a powerful Profinet IO-RT/IRT chip set. The integrated switch obviates the need for additional switching devices at the installation location. Several proxies can, for example, be switched together in a row. The proxy supports all protocols and functions required for Profinet. In particular, this includes the Lower LinkLayer Discovery Protocol (LLDP) for reading out topology information from the network. Both proxies therefore offer consistent, vertical integration of Interbus into any given Profinet-capable control system.

For more information contact Phoenix Contact on +27 (0)11 801 8200, [email protected], or www.phoenixcontact.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Beckhoff expands economy drive system
Beckhoff Automation Fieldbus & Industrial Networking
: Beckhoff’s new AM1000 servomotor joins the company’s economy drive system. The compact, powerful motor and the AX1000 servo drive provide users with a perfectly coordinated, cost-optimised drive system.

Read more...
CC-Link IE Field supports egg carton production
Fieldbus & Industrial Networking
Huhtamaki’s Franeker plant in the Netherlands manufactures more than 11 million egg cartons every week using recycled paper. To support its highly automated lines, the site has begun upgrading its automation systems from older serial network standards to CC-Link IE Field, an open industrial Ethernet technology that offers faster performance due to gigabit bandwidth and better diagnostics.

Read more...
Ultra-compact industrial PCs exploit advances in CPU technology
Beckhoff Automation Fieldbus & Industrial Networking
Beckhoff’s C60xx scalable series of ultra-compact industrial PCs combines high computing power in an extremely compact format with a wide range of options for installation in the control cabinet.

Read more...
How to protect your industrial network
RJ Connect Editor's Choice Fieldbus & Industrial Networking
Network security is no longer a matter of preventing hacking or data breaches. Traditional defence mechanisms for perimeter protection may not fully address internal threats or device-level vulnerabilities alone.

Read more...
High-speed precision and simplified architecture for slicing systems
Fieldbus & Industrial Networking
When KFT Food Machinery needed a way to support ultra-fast, multi-axis motion control in its slicer range, it turned to CC-Link IE TSN – the open industrial Ethernet technology from the CC-Link Partner Association (CLPA).

Read more...
Precise, synchronised control for automated steel mesh handling system
Fieldbus & Industrial Networking
Automation specialist Hambi Maschinenbau has developed a world-first system that automates the cutting, handling and stacking of heavy reinforcing steel mesh – a task that previously required up to six human operators.

Read more...
Loop Signature Part 2-1: Loop signatures and process transfer functions
Michael Brown Control Engineering Fieldbus & Industrial Networking
The previous series of loop signature articles dealt with the basics of control loop optimisation, and concentrated on troubleshooting and ‘SWAG’ tuning of simple processes. In this new series, consideration will be given to dealing practically with more difficult issues like interactive processes, and with processes with much more complex dynamics.

Read more...
Smart and seamlessly integrated I/O upgrade
Beckhoff Automation Fieldbus & Industrial Networking
Beckhoff’s entire portfolio of EtherCAT terminals is now undergoing a technological upgrade while remaining fully compatible with the existing series.

Read more...
Introduction to Part 2 loop signatures and process transfer functions
Fieldbus & Industrial Networking
The previous series of loop signature articles dealt with the basics of control loop optimisation, and concentrated on troubleshooting and ‘SWAG’ tuning of simple processes. In this new series, consideration will be given to dealing practically with more difficult issues like interactive processes, and with processes with much more complex dynamics.

Read more...
Siemens sets new standards in drive technology
Fieldbus & Industrial Networking
Siemens is setting new standards in industrial drive technology with the launch of its new high-performance drive system, Sinamics S220. This offers a seamless and innovative drive system with comprehensive simulation and analysis capabilities and advanced connectivity features that enable full integration into digital work processes.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved