Flow Measurement & Control


Liquid mass flow sensors with OEM applications

November 2006 Flow Measurement & Control

Precise, compact and fast - those were the objectives for the engineers at Bronkhorst High-Tech for its new digital mass flow meters for liquids. The result is the product series LIQUIFLOW L10/L20.

As successor to the successful analog LIQUI-FLOW series L1/L2, the latest instruments are available within the range of 0,1 g/h and 1 kg/h as either a flowmeter or, with optional control valve, as a compact flow controller. The pressure rating for the instruments is 100 bar (10 MPa). The stainless steel sensor has negligible internal volume and no moving parts. The instruments are metal sealed. As the sensor elements are not in direct contact with the liquid, the sensor is suitable for aggressive fluids.

Calibration of the mass flowmeters or controllers can be performed for virtually every liquid and up to eight calibration curves can be stored onboard the instrument itself. In addition, the digital instruments feature fast response (< 2 seconds) and high precision (1% FS or better). The instruments have analog I/O-signals and also an RS232 connection as a standard feature. In addition to this, there is the possibility of integrating an interface board with DeviceNet, Profibus-DP, Modbus or Flow-Bus protocol.

Flow control can be achieved by utilising the integrated PID-control function on the liquid flowmeter in combination with an optional control valve or pulsation free rotary positive displacement pump. Due to its small dimensions, the sensor can also be applied in OEM-systems, for instance in analytical applications, in customer specific designs.

Mecosa is the sole agent for Bronkhorst High-Tech in South Africa.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Hygienic flow measurement for the food industry
ifm - South Africa Flow Measurement & Control
With the SMF magnetic-inductive flow meter, ifm offers a solution for the hygienic flow measurement of media with variable flow rates through a pipe, such as beer, milk or fruit juice.

Read more...
Case History 197: Bad reboiler temperature control.
Michael Brown Control Engineering Editor's Choice Flow Measurement & Control
It is very important that reboiler temperature controls operate well in petrochemical refineries, or the product quality can really suffer. I was asked to check such a control in a refinery where they were having problems with one of these controls.

Read more...
Precision measurement for ultra-pure water systems
Anton Paar Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Groundbreaking measurement system
Mecosa Level Measurement & Control
Berthold Technologies has launched the LoopSeries LB 430, an innovative, industry-leading measurement system designed to enhance operational efficiency with advanced level, density, and level switch capabilities.

Read more...
Eliminating splashbacks, spills and early shutoffs in ultra high-flow fuelling
Flow Measurement & Control
Husky Corporation has unveiled the latest innovation in fuelling technology with its newly designed StreamShaper for ultra high-flow applications, which minimises early shutoffs and splashback spills.

Read more...
Radiometric density measurements
Mecosa Flow Measurement & Control
Radiometric density measurements are used wherever conventional measurement techniques fail. Successful applications can be found in a wide variety of industries, especially where harsh process environments and difficult measuring conditions prevail.

Read more...
Battery-powered magmeter
Flow Measurement & Control
The RWEM/D battery-powered electromagnetic flow meter from Royce Water Systems is ideal for water and wastewater systems located at remote sites.

Read more...
Precise process and maximum savings with VEGABAR
VEGA Controls SA Flow Measurement & Control
Accurate measurementsof differential pressure is crucial for safety, efficiency and optimising operational processes. For over 40 years, VEGA has supplied industry-leading pressure measurement solutions, establishing itself as a trusted expert with a proven track record in sensor technology.

Read more...
Innovative solutions for low flow dosing with high precision
Mecosa Flow Measurement & Control
n the food, pharma, and chemical manufacturing industries, precision and efficiency are of utmost importance. Bronkhorst High-Tech has developed a flexible solution that meets today’s requirements for highly accurate dosing, whether continuous, in ratio, or in batches.

Read more...
Battery-powered magmeter
Flow Measurement & Control
The RWEM/D battery-powered electromagnetic flow meter from Royce Water Systems is ideal for water and wastewater systems located at remote sites.

Read more...