Instrotech now offers Keller’s range of intrinsically safe electronic pressure gauges for use in areas subject to gas explosion risks. The type approvals are compliant with the ATEX Explosion Protection Directive regarding explosive gases. The electronic design of these devices is trimmed to minimise energy consumption, so it is also possible to replace the batteries inside areas with explosion risks.
The simplest version, model ECO 1 Ei, offers high resolution and reproducibility for both measuring ranges (-1 to 30 bar and 0 to 300 bar), together with accuracy (typical) of 0,5% FS and an integrated min/max memory. The application range as per the ATEX directive is defined by identification markings Ex ia IIC T5 or T6.
Keller’s type Leo 1 Ei and LEO 2 Ei electronic pressure gauges feature microprocessor-assisted compensation to ensure an extremely narrow total error band (including temperature errors) of 0,2 % FS over the entire range of operating temperatures from 0-50°C. The zero point can be selected freely within the four measuring ranges and an automatic switch-off function guarantees energy efficiency. Both models feature sampling rates of 2 Hz and integrated min/max memories. The special feature of the Leo 1 Ei is its additional memory for peak values. In peak mode, even extremely short-lived peak values for system pressure are registered with a sampling rate of 5000 Hz. For both these pressure gauges, the application range as per the ATEX directive is defined by identification markings Ex ia IIC T5 or T6.
Another version of the Leo type electronic pressure gauge, the Record Ei, is equipped with an integrated data memory to record pressure and temperature progressions in the measuring medium. Outside of areas with explosion risks, the data can be transmitted via an RS-485 interface to a PC for evaluation with the Logger 4.X software. The instrument can register pressures of up to 1000 bar with a total error band of 0,1% FS. With a capacitive sensor, this type is also available for very low measuring ranges starting from 30 mbar. The application range as per the ATEX directive is defined by identification marking Ex ia IIC T4.
Featuring accuracy of up to 0,01% FS, the Lex 1 Ei electronic pressure gauge is a genuine reference and precision measuring instrument that has been specifically equipped with a 5-digit display for calibration and testing purposes. Pressure measurement ranges of between -1 and 1000 bar are available. This device also offers a min/max memory and a digital interface to generate PC protocols. The application range as per the ATEX directive is defined by identification marking Ex ia IIC T6.
Features that are shared by all Keller digital pressure gauges include simple parameterisation and operation with only two buttons, while the pressure display can be shown in various physical units that are freely selectable.
VEGA handles the pressures of water treatment systems VEGA Controls SA
Pressure Measurement & Control
A water treatment system for a major metropolitan area in the Midwestern United States demands careful monitoring and management of processes across its sprawling network. Choosing VEGA for its process automation needs meant more than just obtaining precise and reliable pressure sensors.
Read more...Monitoring the health of systems SA Gauge
Pressure Measurement & Control
Pressure and temperature gauges are vital instruments in various industries. However, they are susceptible to failures that can compromise their accuracy and reliability. When these gauges fail, the consequences can be severe.
Read more...Enhancing beer brewing precision VEGA Controls SA
Pressure Measurement & Control
Brewing beer is a complex process that requires utmost precision in every step. To ensure precision, it is crucial to measure and control the pressure and point levels in the wort kettle and hops dissolver. Using VEGA instrumentation can offer numerous benefits to breweries.
Read more...Custom solutions for pressure measurement Instrotech
Sensors & Transducers
Wherever pressure sensors are needed, a solution can normally be found in the Keller product catalogue. However, there are often great benefits to optimising a product specifically for integration and use in complete existing systems.
Read more...Greener mining through water management strategies VEGA Controls SA
Pressure Measurement & Control
Water scarcity is a pressing concern in South Africa, leading to the establishment of stricter regulations on water discharge and management. To promote greener mining operations that minimise environmental impact and optimise resource utilisation, responsible dewatering practices are essential.
Read more...Pressure sensors for hydrogen applications Instrotech
Pressure Measurement & Control
Keller manufactures isolated piezoresistive pressure sensors. The great advantage of the piezoresistive measuring principle is its high stability.
Read more...A new approach to milk processing VEGA Controls SA
Pressure Measurement & Control
Ensuring the quality and safety of milk throughout the production process is of the utmost importance in the dairy industry. Process instrumentation plays a vital role in this stage by providing accurate measurements of level, pressure and point level to guarantee optimal storage conditions.
Read more...Sensor technology for cartonboard machine for paper and packaging VEGA Controls SA
Pressure Measurement & Control
Paper and packaging specialist, LEIPA undertook a comprehensive modernisation project, combining three stock preparation lines into one, and making investments in new plant components and extensive automation technology. Because of the good experiences the company had already had with VEGA sensors, those responsible for planning and maintenance decided in favour of the VEGABAR 82 pressure transmitter as the standard instrument for level and pressure measurement in the new stock preparation system.
Read more...Pressure measurement without risk of contamination WIKA Instruments
Pressure Measurement & Control
Injectables are among the most sensitive products in the pharmaceutical industry. Sterility is essential during production. For this reason, a manufacturer of biopharmaceuticals decided to implement the pressure monitoring of its processes with hygienic instruments from WIKA.