Maintenance, Test & Measurement, Calibration


Remove water from factory air

Technews Industry Guide: Sustainable Manufacturing 2021 Maintenance, Test & Measurement, Calibration

A leading cause of costly downtime and emergency maintenance is water vapour and the resulting condensed water that is trapped in factory compressed air.

Water in facility airlines can cause corrosion, rust and pipe scale, which can break loose to block or adhere to air passageways, and lead to increased pressure drop and loss in machine performance. Machine components will suffer premature wear and parts deterioration from water:

• Pneumatic cylinders will have their pre-lubricants washed away, corrode and respond slower.

• Solenoid valves’ rubber seals will stiffen and become more susceptible to rupturing and leaking.

• Instrumentation can malfunction even with the presence of only a small amount of moisture.

• Air powered tools will likely stick and perform less efficiently.

End products are also at risk of suffering quality deterioration because of water:

• Spray painting will be adversely affected by change in colour, adherence and finish quality.

• Industrial ink-jet printers will be adversely affected by change in adherence and finish quality.

• Blow moulding plastic bottles’ viscosity and material consistency could be adversely affected.

• Glueing/taping adhesiveness of cardboard boxes could be adversely affected.

• Pharmaceutical mixing and integrity could be adversely affected.

• Food processing may be contaminated because of micro-organism growth.

How does water vapour enter factory compressed air?

All atmospheric air contains contaminants and water vapour that is concentrated during the compression process. The heat generated during compression increases the capacity of the compressed air to hold moisture, thus avoiding condensation inside the compressor. Lubricants used to improve the efficiency and life of the compressor also become part of the contaminant load, as do wear particles.

A compressor with a 75 kW capacity, operating at 30°C ambient temperature, a relative humidity of 80%, compressing air to 7 bar, can produce approximately 113 litres of condensate during an eight-hour shift.


Removing liquefied water from factory compressed air

Aftercoolers

The compressed air exiting the compressor can reach temperatures as high as 150°C, which is unusable for industrial applications. This hot, saturated air will release 70-80% of its excess water vapour if simply cooled to near room temperatures. To achieve this type of cooling and bulk moisture removal, air- or water-cooled aftercoolers are often employed. Condensed liquid is removed from the aftercooler via automatic condensate drains.

The air exiting the aftercooler will still be saturated but at a much more manageable temperature. Because the air is at a dew point of 37°C or more, it is still vulnerable to further condensation into liquid water should it be exposed to temperatures lower than this dew point. The piping in most industrial facilities would allow for further temperature fluctuation, thereby allowing more condensation to take place as the air moves through the plant.


Drip legs

The next line of defence for removing the water is a drip leg. This is a vertical pipe plumbed at the air drop line (below the horizontal header pipe) to allow water to be drained away using the principle of rapid air expansion to condense water vapour into liquid water. The condensate is then removed by a drain at the bottom of the drip leg, which can be automatically or manually drained to avoid overflow of contaminants.

Water separators

Water separators use mechanical separation techniques to remove condensed water in bulk from factory air, either by directing inlet air into a spiral and using centrifugal force to separate the water out from the compressed air, or by passing the inlet air through a special resin filter element with large meshes to trap water particles that will drop down to a collection bowl allowing the compressed air to pass through.

SMC’s AMG Series water separator can remove water droplets (up to a 99% removal rate) using a special resin filter. It is easy to install and requires no electrical power.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

WearCheck leads the way in condition monitoring
Wearcheck Maintenance, Test & Measurement, Calibration
Minimising maintenance costs of mining and power-generating machinery and maximising its operational efficiency – these goals form the foundation of the proactive/preventive maintenance services provided by the expert technicians at condition monitoring specialist, WearCheck.

Read more...
Collect data three times faster
SKF South Africa Maintenance, Test & Measurement, Calibration
SKF has extended its renowned Microlog Analyzer family of data collection devices with the addition of the Microlog Analyzer dBX. Currently SKF’s most powerful diagnostic tool, this cutting-edge device redefines diagnostic capabilities, enabling users to take measurements three times faster than its predecessor.

Read more...
Integrated liners for the mining industry
Maintenance, Test & Measurement, Calibration
Multotec has developed a range of composite integrated mill liners in response to the needs of local and international mining clients.

Read more...
Selection of two-port valves: an open and shut case
SMC Corporation South Africa Valves, Actuators & Pump Control
Little consideration is generally given to two-port valves because they are often perceived as simple devices that only open and close to control downstream fluid supply. Although this is mechanically true, choosing the optimal two-port valve for your application can make a big difference, saving space, weight and energy consumption.

Read more...
The criticality of maintenance in the water and wastewater segment
Schneider Electric South Africa Maintenance, Test & Measurement, Calibration
In a time of water shedding, climate change and ageing infrastructure, the importance of maintenance and support in the water and wastewater segment cannot be overstated.

Read more...
How dry ice blasting is revolutionising the mining industry
Maintenance, Test & Measurement, Calibration
Dry ice blasting has emerged as a game-changing technology for the mining industry, offering a range of advantages that are reshaping traditional cleaning methods.

Read more...
Quality test tools save costs at pulp and paper mill
Comtest Editor's Choice Maintenance, Test & Measurement, Calibration
A case study on how preventive maintenance and a few good test tools avoided unnecessary motor replacements at a pulp and paper company.

Read more...
Selection of two-port valves: an open and shut case
SMC Corporation South Africa Valves, Actuators & Pump Control
Little consideration is generally given to two-port valves because they are often perceived as simple devices that only open and close to control downstream fluid supply. Although this is mechanically true, choosing the optimal two-port valve for your application can make a big difference, saving space, weight and energy consumption.

Read more...
Effect of static electricity on overall equipment effectiveness
SMC Corporation South Africa Electrical Power & Protection
Have you ever tried to remove the dust from your TV screen? It’s not easy. TV screens accumulate static charge during use, so trying to remove dust with a cloth becomes seemingly impossible because ...

Read more...
The logical solution to oil and gas industry corrosion
Maintenance, Test & Measurement, Calibration
The consequences of corrosion in the oil and gas industry can be astronomical. The simple culprit is metal reacting with oxygen and moisture, degrading it back to its natural state.

Read more...