Flow Measurement & Control


Key factors for picking the optimal flowmeter

July 2021 Flow Measurement & Control

Flowmeters play a pivotal role in many applications, but some may underperform if they’re not the best match for a process. Making assumptions about a flowmeter going into an oil or gas application can lead to an expensive mistake, especially in high-pressure situations. While a variety of factors impact meter performance, the most common culprits are flawed sizing and failing to choose the most appropriate technology.

By more closely accounting for these and other variables – and not going into the evaluation fixed on a specific meter technology – operators can ensure their future flowmeter acquisitions are better suited for the job.

Pay close attention to sizing

Sizing is an issue because meters tend to be designed to potential maximum flows instead of actual operating flow rates. Is a meter the proper size for the flow rate, pressure and temperature at which it will typically be operating? Because gas is compressible, for example, sizing a meter for maximum design pressure will provide a flow rate in standardised volumes that appears much different than it would be at normal operating pressure. In that case, selecting a flow meter to handle 135 bar based on the pipeline design, even though it will really operate at 35 bar, will result in a meter that is substantially oversized for the application.

To mitigate these types of sizing issues, ask the vendor for a sizing report or for software to perform the sizing. Plug all the flow variables – fluid type, flow rate, pressure, temperature, viscosity, compressibility, and density – into the software. It will provide recommended technologies as well as an estimate of the devices’ performance to help select the most suitable meter.

However, sizing software can only go so far, as another common issue is not selecting the technology that’s the optimal fit for an application. For example, if there are corrosion inhibitors in a fluid, it would be inappropriate to use an electromagnetic meter since the additive may inadvertently be coating the sensor electrodes and thereby affecting the sensitivity of the device to flow changes. Account for any special considerations, such as the potential explosiveness or corrosiveness of what’s being measured. Additionally, are there any electrical or hazardous materials approvals required for the technology to fit in an installation? Asking these types of questions will help you to determine material compatibility and narrow down the most appropriate options.

Other variables to watch

While proper sizing and choice of meter based on materials is critical, there are other fundamentals to consider when evaluating flow meters. These include:

• Be clear on what is required when it comes to accuracy, repeatability and pressure drops at nominal operating conditions. A greater pressure drop might be acceptable in some settings, but not in others. Most manufacturers’ sizing software will provide several meter options that span a range of accuracy and pressure drops.

• Have a clear understanding of what’s being measured and its overall state. While this seems straightforward, there can be confusion in some instances. This may impact where and how you choose to install the meter, so consult the manufacturer if these types of conditions apply.

• Mechanically, what kind of flanges or end connections will be needed to mount the instrument? If the new flowmeter is replacing an existing meter, understand the dimensions of what’s being replaced. For example, what will be required to adapt a new meter selected as a replacement for a mechanical device with a narrow facing.

• Have a clear understanding of the power requirements, environmental conditions and how the meter will connect to other devices. A meter tied into a control system might elicit a different set of recommendations from a vendor than one that will be operating independently or remotely connected to a scada system.

Finding an optimal flowmeter solution depends on knowing as much as possible about the application. By asking the right questions and taking these variables into consideration you are more likely to find the best device for the application.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Radiometric density measurements
Mecosa Flow Measurement & Control
Radiometric density measurements are used wherever conventional measurement techniques fail. Successful applications can be found in a wide variety of industries, especially where harsh process environments and difficult measuring conditions prevail.

Read more...
Battery-powered magmeter
Flow Measurement & Control
The RWEM/D battery-powered electromagnetic flow meter from Royce Water Systems is ideal for water and wastewater systems located at remote sites.

Read more...
Precise process and maximum savings with VEGABAR
VEGA Controls SA Flow Measurement & Control
Accurate measurementsof differential pressure is crucial for safety, efficiency and optimising operational processes. For over 40 years, VEGA has supplied industry-leading pressure measurement solutions, establishing itself as a trusted expert with a proven track record in sensor technology.

Read more...
Innovative solutions for low flow dosing with high precision
Mecosa Flow Measurement & Control
n the food, pharma, and chemical manufacturing industries, precision and efficiency are of utmost importance. Bronkhorst High-Tech has developed a flexible solution that meets today’s requirements for highly accurate dosing, whether continuous, in ratio, or in batches.

Read more...
Battery-powered magmeter
Flow Measurement & Control
The RWEM/D battery-powered electromagnetic flow meter from Royce Water Systems is ideal for water and wastewater systems located at remote sites.

Read more...
Smart technology for municipal services
VEGA Controls SA Flow Measurement & Control
A new wave of smart technologies has emerged from VEGA Instruments, promising a revolutionary impact on the efficiency and dependability of municipal services.

Read more...
KROHNE reaches important milestone in Ethernet-APL
KROHNE Fieldbus & Industrial Networking
In December 2023, KROHNE made Ethernet-APL demo devices available to selected customers. This step marks an important milestone in the company’s own Ethernet APL development project for various sensor types. Ethernet-APL technology is a revolution in the process industry.

Read more...
Sustainable journey with hydrogen
Mecosa Flow Measurement & Control
Bronkhorst High-Tech, the Dutch leader in flow measurement and control, has been focusing on hydrogen applications in the renewable energy market for some time, and for good reason.

Read more...
Wireless communication system for remote access to data
KROHNE Data Acquisition & Telemetry
KROHNE has introduced the OPTIBRIDGE 3880 IIoT data logger for remote data services, acquisition and evaluation. It is a fully autonomous battery- or mains- powered wireless communication system for remote access to measurement data.

Read more...
Optimise sludge treatment and reduce operational costs
Endress+Hauser South Africa Flow Measurement & Control
The Endress+Hauser inline measuring devices, the Proline Teqwave MW 300 and the Proline Teqwave MW 500, determine the total solids content of wastewater directly through microwave transmission.

Read more...