Flowmeters play a pivotal role in many applications, but some may underperform if they’re not the best match for a process. Making assumptions about a flowmeter going into an oil or gas application can lead to an expensive mistake, especially in high-pressure situations. While a variety of factors impact meter performance, the most common culprits are flawed sizing and failing to choose the most appropriate technology.
By more closely accounting for these and other variables – and not going into the evaluation fixed on a specific meter technology – operators can ensure their future flowmeter acquisitions are better suited for the job.
Pay close attention to sizing
Sizing is an issue because meters tend to be designed to potential maximum flows instead of actual operating flow rates. Is a meter the proper size for the flow rate, pressure and temperature at which it will typically be operating? Because gas is compressible, for example, sizing a meter for maximum design pressure will provide a flow rate in standardised volumes that appears much different than it would be at normal operating pressure. In that case, selecting a flow meter to handle 135 bar based on the pipeline design, even though it will really operate at 35 bar, will result in a meter that is substantially oversized for the application.
To mitigate these types of sizing issues, ask the vendor for a sizing report or for software to perform the sizing. Plug all the flow variables – fluid type, flow rate, pressure, temperature, viscosity, compressibility, and density – into the software. It will provide recommended technologies as well as an estimate of the devices’ performance to help select the most suitable meter.
However, sizing software can only go so far, as another common issue is not selecting the technology that’s the optimal fit for an application. For example, if there are corrosion inhibitors in a fluid, it would be inappropriate to use an electromagnetic meter since the additive may inadvertently be coating the sensor electrodes and thereby affecting the sensitivity of the device to flow changes. Account for any special considerations, such as the potential explosiveness or corrosiveness of what’s being measured. Additionally, are there any electrical or hazardous materials approvals required for the technology to fit in an installation? Asking these types of questions will help you to determine material compatibility and narrow down the most appropriate options.
Other variables to watch
While proper sizing and choice of meter based on materials is critical, there are other fundamentals to consider when evaluating flow meters. These include:
• Be clear on what is required when it comes to accuracy, repeatability and pressure drops at nominal operating conditions. A greater pressure drop might be acceptable in some settings, but not in others. Most manufacturers’ sizing software will provide several meter options that span a range of accuracy and pressure drops.
• Have a clear understanding of what’s being measured and its overall state. While this seems straightforward, there can be confusion in some instances. This may impact where and how you choose to install the meter, so consult the manufacturer if these types of conditions apply.
• Mechanically, what kind of flanges or end connections will be needed to mount the instrument? If the new flowmeter is replacing an existing meter, understand the dimensions of what’s being replaced. For example, what will be required to adapt a new meter selected as a replacement for a mechanical device with a narrow facing.
• Have a clear understanding of the power requirements, environmental conditions and how the meter will connect to other devices. A meter tied into a control system might elicit a different set of recommendations from a vendor than one that will be operating independently or remotely connected to a scada system.
Finding an optimal flowmeter solution depends on knowing as much as possible about the application. By asking the right questions and taking these variables into consideration you are more likely to find the best device for the application.
Tel: | +27 11 314 1391 |
Email: | [email protected] |
www: | www.za.krohne.com |
Articles: | More information and articles about KROHNE |
© Technews Publishing (Pty) Ltd | All Rights Reserved