Up to now, data has been distributed across many devices at the field level. Turck is paving the way for the evaluation of this data with its high-availability I/O system, excom. Its GEN-3G Ethernet gateway provides an interface for parallel data access. In this way, users can transfer process information and metadata from the field to IT systems. There, intelligent condition monitoring algorithms transform this data into knowledge that helps manage the plant.
Tamper-proof data access
The excom Ethernet gateway is approved for installation in Zone 2 Ex areas or in safe areas. It not only transmits usage data to the control system via multiprotocol Ethernet (Profinet, EtherNet/IP, Modbus TCP) – in addition to this user data, analysis data can be retrieved from the gateway by suitable network participants and transferred to outsourced IT systems.
These run in parallel over the same network. The IT system for data analysis has read authorisation only, which prevents tampering with the process or control systems. The systems for data analysis can be realised on premises without an external network connection, or in cloud systems.
The excom is a high-availability I/O system that consistently implements the system concept. Optimised system components are available for use in safe areas as well as in Zone 2 and Zone 1 (with Profibus DP). Nevertheless, users can control all zones and system parts via a DTM, EDS or GSDML and the same structure and logic. This minimises the training requirements and increases the flexibility of operators.
The system connects I/O level and explosion isolation in a single housing. This allows space-saving, central installations to be implemented in the instrumentation and control room as well as decentralised I/O solutions for installation in Zone 2 or even up to Zone 1 (with Profibus DP).
No re-approval required, even for extensions
The entire system is approved for the corresponding Ex areas. Users can therefore exchange or even supplement gateways or I/O cards flexibly. The operators can carry out the necessary re-evaluation of the temperature in the system housing themselves, without an external test site.
excom systems are installed and wired in a control cabinet or individual enclosure, taking account of specific application requirements. Individual cable glands, terminals, system connectors and other components can be installed directly. Depending on the project, the factory acceptance test (FAT) can be performed directly at Turck’s site, meaning users need only one partner for their turnkey I/O systems.
Inductive IO-Link sensors Turck Banner Southern Africa
Sensors & Transducers
Turck Banner is expanding its sensor range, with inductive measuring sensors with IO-Link and an analogue output for flush and non-flush mounting.
Read more...Field service regime key for effective PDS/CPS operation
IS & Ex
While their primary objective is to ensure the safety of people, proximity detection system and collision prevention system installations also have a direct bearing on other critical parameters such as equipment availability and productivity.
Read more...New toolset for Turck Automation Suite Turck Banner Southern Africa
Industrial Wireless
Turck is expanding its Turck Automation Suite IIoT and service software platform with the TAS Cloud industrial cloud service for remote maintenance and condition monitoring.
Read more...Condition monitoring to go Turck Banner Southern Africa
Fieldbus & Industrial Networking
Anyone who wants to efficiently monitor the climate in control cabinets will find a comprehensive range of control cabinet monitors for the DIN rail in Turck Banner’s cabinet condition monitoring family.
Read more...Energy measurement module for BL20 I/O System Turck Banner Southern Africa
Electrical Power & Protection
Turck’s BL20 energy measurement module enables precise monitoring of the energy consumption of single- or three-phase systems.
Read more...Compact UHF RFID reader with integrated Ethernet interface Turck Banner Southern Africa
Industrial Wireless
Online teaser: Turck Banner’s Q150 UHF RFID reader has an integrated Ethernet interface. The IP67 reader communicates directly with PC or PLC systems in industrial Ethernet networks having the four most important protocols, without the need for an additional interface.
Read more...Monitoring voltage continuously Turck Banner Southern Africa
Electrical Power & Protection
Get a more comprehensive view of equipment and overall plant health while improving the accuracy of power calculations with Turck Banner’s new AC voltage sensor.
Read more...Magnetic field/temperature sensor with IO-Link Turck Banner Southern Africa
Temperature Measurement
Turck Banner’s CMMT condition monitoring sensor detects magnetic field changes on three axes, and thus opens up new application fields.
Read more...Powerful measuring sensor with two new modes Turck Banner Southern Africa
Sensors & Transducers
Turck Banner has launched two new modes in the Q2X series of miniature photoelectric sensors: laser measurement and fixed-field.
Read more...World’s first 5G smartphone for ATEX and IECEx zone 1/21 Extech Safety Systems
IS & Ex
i.safe MOBILE has launched the world’s first 5G smartphone for ATEX and IECEx zone 1/21. The intrinsically safe mobile device, which was also developed for use in 5G campus networks, offers companies great flexibility thanks to its wide range of possible applications, especially in the automation sector.