Temperature Measurement


Common causes of thermocouple temperature measurement errors

April 2018 Temperature Measurement

Thermocouples are among the most popular temperature measurement instruments in industrial applications because of their versatility and ease of use. However, measurement errors can occur. They are robust temperature measurement devices that are accurate enough for many industrial and scientific applications. Relatively inexpensive compared to other temperature measurement technologies, thermocouples are valued for their ability to measure a wide temperature range from -200 to 1250°C.

Thermocouples measure temperature differentials, not absolute temperatures. Two wires, each made from a different metal, are joined at the tip. This is the measuring junction. At the other end, the wires are connected to a body of a known temperature, called the reference junction. A thermocouple works by taking the difference in voltage between the two junctions, explained by the Seebeck effect. The measured voltage is converted into a temperature unit, with the temperature reading displayed on a device or transmitted to a remote location.

Although thermocouples are reliable, temperature measurement errors can occur for various reasons. The following are the six most common causes of thermocouple measuring errors:

1. Selecting the wrong type of thermocouple on the transmitter

Problems can occur if the wrong type of thermocouple is chosen when inputting the settings into the transmitter during installation. This is a common error as there are numerous types of thermocouples – types K, J, N, E, T, R, S, and B – each with a different range, accuracy and electrical output.

Solution: Almost all thermocouples are colour coded by type, so all that is needed is to confirm the colour of the thermocouple jacket and match the settings on the transmitter.

2. Problems related to the thermocouple extension wire

If the polarity of the thermocouple lead wires is accidentally reversed, the measured temperature will be incorrect by the difference in temperature of the two ends of the leads. The problem is understandable because red is the usual colour for positive charges, whereas the red wire in thermocouple cables typically contains the negative signal. This colouration is ANSI standard for thermocouples, but it is not what most people expect.

Solution: Doublecheck the connection and, if necessary, swap the thermocouple lead wires.

3. Inherent variations in alloys

No two batches of wires are exactly alike. As the alloy percentages vary a tiny bit during each manufacturing process, some error in thermocouple accuracy is unavoidable. Standard thermocouples get within approximately 1% of the actual temperature at the measuring junction, which is accurate enough for most applications.

Solution: Order thermocouples with special-limit wires, which can improve accuracy twofold. These wires are manufactured at the highest tolerances to ensure the fewest possible impurities and the greatest consistency in alloy ratio.

4. Temperature variations around the reference junction connection

Because a thermocouple measures temperature differentials, any temperature fluctuations around the reference junction (cold junction), which has the known temperature, result in an erroneous temperature reading.

Solution: Make sure no fans or other sources of cooling or heating are located near the reference junction. Simple insulation can also protect the junctions from extreme temperatures.

5. Thermocouple grounded at more than one location

A thermocouple should be grounded at only one location. If it is grounded at more than one location, a ‘ground loop’ can be created with current flowing through the thermocouple from one ground to the other. This is likely to generate electromagnetic fields, which can lead to radio frequency interference related problems that can impact measurement accuracy.

Solution: Ground either the transmitter (connection head) or the controller/recorder, but not both. Selecting transmitters that have internal isolation between the input, output and ground usually provides enough isolation to eliminate a ground loop. Loop isolators are also available and can be put in the loop wiring circuit to prevent this from happening.

6. Thermocouple age

While thermocouples are reliable temperature measurement devices, they do drift with time. Maximum exposure temperature, cyclic measurements, and frequency of the cycles affect the metallurgy with a resultant drift, usually downward. Unfortunately, this drift cannot be predicted, but 5 to 10°C errors are common.

Solution: The only solution is to replace the thermocouple periodically based on the user’s experience.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Rapid, precise pressure control for industrial applications
WIKA Instruments Pressure Measurement & Control
The CPC3050 high-speed pressure controller delivers rapid, precise pressure control for industrial applications, achieving three-point verification in ten seconds.

Read more...
Proven indicators monitored in three dimensions
ifm - South Africa Temperature Measurement
The VVB30x continuously detects vibrations in three measurement axes and uses them to calculate proven indicators for evaluating machine condition.

Read more...
Three ways to conduct thermal inspections
Comtest Temperature Measurement
There’s no universal solution for all infrared inspections with a Fluke thermal camera, also known as a thermal imager. You need to match your method to the type of equipment you’re inspecting and the level of detail you require.

Read more...
Modern N1020 temperature controller
Temperature Measurement
Temperature control is a fundamental aspect of maintaining the integrity and quality of products in industries such as food processing, pharmaceuticals and healthcare. The N1020 temperature controller, designed for precision and reliability, addresses the stringent requirements of these sectors by offering advanced features and robust functionality.

Read more...
Safer, simpler temperature measurement
ABB South Africa Temperature Measurement
ABB has launched an enhanced version of its NINVA TSP341-N non-invasive temperature sensor, delivering safer and simpler temperature measurements for applications in the chemical, oil and gas industries.

Read more...
Unique industrial asset monitoring solution
WIKA Instruments Sensors & Transducers
WIKA WikaPredict offers a unique industrial asset monitoring solution, combining advanced sensors and artificial intelligence. As a leader in predictive maintenance, it helps clients enhance operational performance and increased efficiency.

Read more...
Smart high-precision pyrometers
Temperature Measurement
LAND, a business of AMETEK, has expanded its range of SPOT+ smart high-precision pyrometers with the launch of the M390, M3-5 and TMT for wider temperature measurement capabilities.

Read more...
Detecting lubrication issues in gearbox testing by IR monitoring
Temperature Measurement
Lubrication is crucial for every transmission gearbox. Thermal imaging cameras such as Instrotech’s PI 640i can quickly and accurately detect temperature variations to ensure that gearboxes are appropriately lubricated.

Read more...
Primary concerns for measuring temperature with thermocouples
Vepac Electronics Temperature Measurement
Temperature values are one of the most common elements measured in any data acquisition system.

Read more...
Is the HVAC market in SA missing the big picture?
Iritron Temperature Measurement
The South African HVAC market is currently grappling with a pervasive mindset that prioritises lowest cost over value for money and technical excellence. However, this approach overlooks the significant benefits that come with investing in high-quality HVAC solutions.

Read more...