Sensors & Transducers


Humidity measurement in poultry farms

August 2017 Sensors & Transducers

Incubation

Eggs are kept in the incubator for a total of 18 days. There are two schools of thought on the correct humidity level to use during this stage. The most popular condition for incubating the eggs is 53% RH @ 37°C. Towards the end of the incubation period, the eggs will start to release CO2, which builds up in the incubator. Valves open to vent this excess and keep the CO2 close to atmospheric levels, which has the side effect of venting water vapour and reducing the humidity level inside, therefore humidifiers are used to compensate for this and keep the level around the required 53%.

Some customers see better uniformity of chicks when they are incubated in a higher humidity initially – 60% or higher in some instances (still at 37°C). They still vent the excess CO2 towards the end of the incubation cycle, but do not replace the water vapour lost at this stage.

If the egg tray is not completely full, then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

The measurement in this environment is fairly clean and after 18 days the eggs are moved to another room. Cleaning methods will vary from site to site, but typically are less invasive. The sensors here typically will have a longer lifetime than those in other areas of the farm.

Hatching

Following the 18 days of incubation, the eggs are moved to the hatcher, where they spend a total of three days. This cycle also begins with a condition of 53% RH @ 37°C. As soon as the chicks begin to hatch, the humidity level naturally increases, up to around 80%. This higher humidity actually assists the other chicks by making the shells slightly softer, allowing them to hatch more easily.

As the chicks hatch, CO2 levels also increase, so ventilation and humidification starts. Once all the chicks are hatched, humidity will be maintained around 60%.

As in the incubator, if the egg tray is not completely full then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

This is a more demanding measurement as the hatching is a messy process. After the chicks are removed, the room will be decontaminated by pressure-washing with a mixture of water and disinfectant. It is this stage which is particularly damaging to the sensor, which should ideally be removed, or at least covered up while this cleaning process is taking place.

Adult chickens

Normal body temperature for chickens is 41,5°C, however this will fluctuate depending on environmental temperature. Maintaining a constant body temperature is not a problem when air temperature is at least 10-15 degrees less than body temperature, but air movement is critical. A bird can only give off heat to its environment if the temperature of that environment is cooler than the bird. If heat produced by the birds is not moved away from them and out of the poultry house quickly, it will be more difficult for them to avoid heat stress.

The ambient temperature should be maintained at <around25°C to avoid stressing the chickens, but more importantly, the environmental temperature should be kept as stable as possible. Fluctuations in the temperature, especially in combination with high relative humidity, will be more stressful to the birds than a high ambient temperature alone.

Measurement

This is the toughest measurement of the three as any sensors installed into the living environment or on the air outlets will experience drift over time, due to the NH3 content in the air. There is also a significant amount of dust, which can cause premature failure on sensors with inadequate filtration.

By far the best location for controlling this environment is on the fresh air inlet.

Cleaning will also periodically take place in this environment, and the same precautions should be followed as in the hatchery, the sensors should be either removed or covered to prevent irreversible damage.

Michell’s HydroSmart HS3 probe

The probe is proven to be a suitable product for withstanding the conditions described above, if the following precautions are adhered to:

• Probes should be mounted in a vertical orientation.

• Probes should always be covered, or ideally removed completely, during decontamination/cleaning cycles.

• Probes should never be cleaned with any kind of solvent, detergent or pressurised water, they should just be wiped down with a damp cloth.

For more information contact Instrotech, +27 (0)10 595 1831, [email protected], www.instrotech.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Optimise sludge treatment and reduce operational costs
Sensors & Transducers
The Endress+Hauser inline measuring devices, the Proline Teqwave MW 300 and the Proline Teqwave MW 500, determine the total solids content of wastewater directly through microwave transmission. This is considerably less time consuming than the process of determining total solids content in a laboratory.

Read more...
Family of analysers for smart and efficient chlorine measurement
ABB South Africa Sensors & Transducers
ABB has launched ChloroStar, a family of sensors, transmitters and accessories for accurate and reliable chlorine measurement and analysis that enable users in the water, wastewater and other industries to control chlorine more efficiently, enhancing treatment and increasing process uptime.

Read more...
The critical role of temperature measurement in flame hardening
Instrotech Temperature Measurement
Flame hardening is a heat treatment process widely used on parts made from mild steels, alloy steels, medium carbon steels and cast iron. Accurate temperature measurement is not just important, but critical for the success of flame hardening.

Read more...
Leading the way with Level 9 PDS implementation
Sensors & Transducers
Applying a Level 9 Proximity Detection System (PDS) to a mining operation is as much about changes in behaviour as it is about technical solutions, according to Pieter Wolfaardt from Apex, Booyco Electronics’ training partner of choice.

Read more...
Enhanced automated weld inspection system
Sensors & Transducers
SmartRay is offering the release of new hardware for its weld inspection system, JOSY, delivering elevated performance and flexibility in the process.

Read more...
Leaders in sensor technology
Gail Norton Instrumentation Sensors & Transducers
Photoelectric eyes have always needed perfect working conditions, but in the workplace there is no such thing. Steam, water, light and dirt interfere with most photoelectric eyes, but never with a Telco sensor.

Read more...
Easy parameter setting of vision sensors
ifm - South Africa Sensors & Transducers
Contour verification and object inspection are two of the most important functionalities in industrial imaging. With the new O2D5xx series, ifm now offers a solution that perfectly masters both functionalities

Read more...
Noncontact infrared temperature control in aluminium rolling process
Instrotech Temperature Measurement
The aluminium rolling process is critical to the aluminium manufacturing industry, where precise temperature measurement is essential for ensuring high-quality product output and protecting equipment. The Optris long-wavelength camera can accurately measure strip temperatures in cold rolling and coiling applications.

Read more...
Keeping a close eye on product quality and purity
Endress+Hauser South Africa Sensors & Transducers
Colour measurements are necessary in many processes to avoid product losses and ensure safe production and batching. The Memosens Wave CKI50 process spectrometer from Endress+Hauser is a compact, robust and process-friendly device allowing quality, batching and phase checks to be performed by a single instrument for the entire visible colour spectrum.

Read more...
The sensory reaction of building management systems
Schneider Electric South Africa Sensors & Transducers
Today’s building management systems (BMS) cannot function properly without sensors. This is so critical that if sensors start failing, they can become ‘blind’.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved