Fluke has introduced its new Fluke 438-II power quality and motor analyser, adding key mechanical measurement capabilities for electric motors to the advanced power quality analysis functions of the Fluke 430 Series II power quality analysers. They measure and analyse key electrical and mechanical performance parameters such as power, harmonics, unbalance, motor speed, torque and mechanical power without the need of mechanical sensors.
The 438-II is the ideal portable motor analysis test tool, locating, predicting, preventing, and troubleshooting power quality problems in three-phase and single-phase power distribution systems, while giving technicians the mechanical and electrical information needed to effectively evaluate motor performance. Features and benefits include:
• Measure key parameters on direct-on-line motors including torque, RPM, mechanical power and motor efficiency.
• Perform dynamic motor analysis by plotting of motor de-rating factor against load according to NEMA guidelines.
• Calculate mechanical power and efficiency without the need for mechanical sensors. Measure electrical parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency.
• Identify power quality issues such as dips, swells, transients, harmonics and unbalance.
• PowerWave data technology captures fast RMS data, and shows half-cycle averages and waveforms to characterise electrical system dynamics.
• Waveform capture function captures 100/120 cycles (50/60 Hz) of each event detected event, in all modes, without set-up.
• Automatic transient mode captures waveform data at 200 kS/s on all phases simultaneously up to 6 kV.
The Fluke 430 Series II Power Quality Analyzers are Fluke Connect compatible, which means that users can view data locally on the instrument, via the Fluke Connect mobile app, or using the PowerLog 430-II desktop software. The series is safety rated for industrial applications.
Prioritising arc flash safety Comtest
Electrical Power & Protection
Comtest has developed a range of thermal imaging and wireless testing tools from Fluke, designed to ensure safety is the top priority for engineers working in potentially dangerous arc flash zones.
Read more...Is the HVAC market in SA missing the big picture? Iritron
Temperature Measurement
The South African HVAC market is currently grappling with a pervasive mindset that prioritises lowest cost over value for money and technical excellence. However, this approach overlooks the significant benefits that come with investing in high-quality HVAC solutions.
Read more...Temperature monitoring in dairies ifm - South Africa
Temperature Measurement
Milk is a natural product whose processing requires precise temperature settings. The Berchtesgadener Land dairy uses innovative temperature sensors from ifm in key process areas.
Read more...No more shocking, inaccurate insulation testing Comtest
Electrical Power & Protection
Fluke has introduced the Fluke 1535 and 1537 2500 V insulation resistance testers, engineered to simplify frontline troubleshooting, whether on the factory floor or working in the field at a solar installation.
Read more...Three ways to conduct thermal inspections Comtest
Temperature Measurement
There’s no universal solution for all infrared inspections with a Fluke thermal camera, also known as a thermal imager. You need to match your method to the type of equipment you’re inspecting and the level of detail you require.
Read more...New temperature relative humidity and barometric pressure transmitter Senseca
Temperature Measurement
ENVIROsense, a new environmental temperature, relative humidity, relative humidity and, optionally, barometric pressure transmitter has been launched by Senseca, a leader in the design and manufacture of monitoring and measurement instrumentation.
Read more...How to test for continuity with a multimeter Comtest
Electrical Power & Protection
Understanding the role of a continuity tester in electrical diagnostics is crucial for professionals and enthusiasts alike. This guide offers a step-by-step approach to using a digital multimeter as a continuity tester, ensuring precise and safe measurements.
Read more...The role of alarm annunciators in temperature monitoring Omniflex Remote Monitoring Specialists
Temperature Measurement
Director at alarm annunciator specialist, Omniflex explores the importance of alarm annunciators in temperature monitoring applications, drawing on examples from different industrial settings.
Read more...Enhanced distribution transformer monitor Comtest
Electrical Power & Protection
Comtest announced that the INCON Distribution Transformer Monitor (DTM) from Franklin Electric Grid Solutions has been updated to include new transformer life prediction functionality, enabling service and maintenance forecasting. This leverages predictive algorithms to estimate the remaining lifespan of transformers, streamlining operations.