Preparing for the 40 Gb/s migration

June 2013 Enclosures, Cabling & Connectors

For this article, I would like to report on the ongoing work and direction of the Next Generation Base-T Study Group in IEEE 802.3. What is driving the development of the next generation of Ethernet Standard over twisted pair copper cabling? Answer, the need for higher speed switch-to-server connections.

Recent trends indicate that a large majority of these network connections will be at 10 Gbps by 2015 and will be migrating to 40 Gbps starting in 2015. The NGBase-T study group is currently focusing on defining the topology, the reach objectives, the cabling requirements and the power consumption of the next generation physical layer interface (PHY).

Let us start by looking at the evolution of the 10GBase-T standard published almost six years ago. Today, 10GBase-T represents about 25% of the switch-to-server market. The main factors that slowed the adoption in the market were the relatively high cost and power consumption of the PHYs compared to 1000Base-T. The first generation 10G Base-T PHYs consumed about 12 watts of power.

Current generation 10GBase-T PHYs, using today’s chip technology, consume considerably less power, between 1,5 to 4 watts depending on the length of the channel. They also take up less space and are more economical. All these advancements are leading to an accelerated deployment of 10GBase-T in the data centre, particularly with the introduction of LAN-on-motherboard (LoM) chips in 2012.

Having learned the lesson from the evolution of 10GBase-T technology, low power consumption is one of the most important considerations for the next generation 40GBase-T PHY. A contribution by Will Bliss of Broadcom is illuminating in this respect. Entitled ‘A Simple Model of Relative Power vs. Reach,’ it shows that the relative power consumption for 40 Gb/s with respect to 10GBase-T is about the same for a reach of 22 metres, about two times more for a reach of 34 metres and four times more for a reach of 46 metres. Every 12 metre increase in reach approximately doubles the power consumption.

In another presentation, Scott Kipp, also of Broadcom, noted that the power consumption can be related to the product of length times the bandwidth. For example, the power consumption of 10G at 100 metres is roughly the same as 40G at 25 metres. The relative power consumption for 40G at 20 metres is approximately 0,8. The relative power consumption for 40G at 10 metres is approximately 0,4. Shorter distances result in considerably less power consumption. The same presentation by Kipp showed that for an ‘end of row topology’ a switch rack at the end of a row can support up to three server racks for a cable distance of 10 metres and 18 server racks for a cable distance of 20 metres. Using a server density of 40 servers/rack, 18 server racks can accommodate 720 servers.

For a ‘middle of row’ topology, with the switch rack located in the middle of a row, a switch rack can support up to 36 server racks or 1440 servers. When a ‘middle of row’ switch rack also supports servers in adjacent aisles, 25 additional racks in each adjacent aisle can be accommodated, for a total of 50 server racks, or 1000 additional servers when using a server density of 40 servers/rack. All this means that with a suitable data centre topology, thousands of high density, rack mounted servers can be supported with a 20 metre link to a modular switch.

Another important consideration in the development of the next-generation Base-T Ethernet standard is the ability to interoperate with legacy slower-speed Ethernet technologies through the function of auto-negotiation.

Compatibility, for auto-negotiation, is facilitated by the use of the 8-pin modular (RJ-45) connector that is currently defined for lower speed Ethernet applications. TIA 42.7 subcommittee is currently developing a Category 8 cabling standard that includes the 8-pin modular connector and 4-pair balanced twisted pair cable that are specified to 2 GHz, which is four times the bandwidth for existing Category 6A cabling.

There was also a joint presentation from Belden, CommScope, Intertek and Fluke Networks that demonstrated the technical feasibility of a cabling system using prototype, Category 8, RJ-45 connectors and prototype Category 8 balanced twisted-pair cables from two different vendors for a short reach (5 m) and long reach (40 m) permanent link configuration. The testing was performed at Intertek, an independent third-party test laboratory, and showed that it is feasible to make components that meet the proposed requirements in the draft Category 8 standard.

What is the main take away from this meeting? After consideration of all the discussion and associated contributions on topology, power consumption and reach, the NGBase-T Study group agreed to the following motions with greater than 75% support, 1) to focus on presentations regarding reach objective in the range of 20 metres to 30 metres, 2) to adopt a 2-connector channel model as an objective.

The above column originally appeared in Cabling Networking Systems, a magazine based in Toronto, Canada. The information presented is the author’s view and is not official TIA correspondence.

For more information contact Greg Pokroy, Jaycor International, +27 (0)21 447 4247, [email protected], www.jaycor.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Cables and wires for food and beverage
LAPP Southern Africa Enclosures, Cabling & Connectors
The strict hygiene regulations for handling foodstuffs stipulate particularly complex requirements for electrical components. The cables and accessories used must withstand a wide range of chemical, thermal and mechanical loads, and also function perfectly at all times in refrigerated and damp rooms.

Read more...
Redefining mobility for fibre cabling
Legrand Enclosures, Cabling & Connectors
As data volumes rapidly increase globally, specialists need to take an urgent look at IT and network infrastructure, with a particular focus on vital equipment like servers, racks and fibre cabling. The Legrand team believes that advanced fibre cabling solutions, which have been developed to simplify deployment, lower costs, improve performance and enable greater densities, will efficiently meet future capacity demands.

Read more...
High-speed data transmission
Enclosures, Cabling & Connectors
Data protocols are constantly evolving to enable interoperability and reliable transfer of increasing amounts of data at the highest speeds between more and more connected devices. To address this technological challenge, Fischer Connectors is expanding its platform capabilities to meet the most demanding connectivity requirements for high-speed data transfer.

Read more...
Robust Ethernet cordset cables
Turck Banner Southern Africa Enclosures, Cabling & Connectors
Turck Banner offers a product range comprising a wealth of different connectors and cables, including over 115 000 connection technology solutions with differing degrees of complexity.

Read more...
What you need to know when you start using hydrogen as your fuel source
Parker Hannifin - Sales Company South Africa Enclosures, Cabling & Connectors
OEMs are taking a more serious look at hydrogen options. Although much of the market is still focused on the potential of battery-powered vehicles, hydrogen fuel cell vehicles offer a viable supplement that is better suited for longer ranges and faster refuelling.

Read more...
SEW-EURODRIVE closes the loop with complete panel solutions
SEW-EURODRIVE Enclosures, Cabling & Connectors
In addition to its quality range of geared motors and related solutions, SEW-EURODRIVE South Africa is ‘closing the loop’ of its products by offering customers electrical control panels as part of the package.

Read more...
Simplify control panel connections
Turck Banner Southern Africa Enclosures, Cabling & Connectors
Panel builders have new tools for bringing power and signals back into protected areas with Turck Banner’s M8 and M12 receptacles.

Read more...
Control cabinet-free automation
Beckhoff Automation Enclosures, Cabling & Connectors
As a replacement for the conventional control cabinet, the MX-System from Beckhoff offers some major efficiency advantages. It also provides a great deal of optimisation potential in terms of the increasing shortage of skilled workers and the expanding presence of DC supply networks across the industry.

Read more...
Cable protection for longer runs
igus Enclosures, Cabling & Connectors
Polymer energy chain manufacturer, igus has introduced a new lighter weight e-chain for cable management and protection applications with large unsupported lengths and high fill weights. This was previously the domain of larger, more expensive energy chains.

Read more...
Panel building should be streamlined
Schneider Electric South Africa Enclosures, Cabling & Connectors
Data centres run critical applications, and require equipment and infrastructure that operate at 100% uptime, as any downtime due to faulty components could have catastrophic ramifications.

Read more...