Preparing for the 40 Gb/s migration

June 2013 Enclosures, Cabling & Connectors

For this article, I would like to report on the ongoing work and direction of the Next Generation Base-T Study Group in IEEE 802.3. What is driving the development of the next generation of Ethernet Standard over twisted pair copper cabling? Answer, the need for higher speed switch-to-server connections.

Recent trends indicate that a large majority of these network connections will be at 10 Gbps by 2015 and will be migrating to 40 Gbps starting in 2015. The NGBase-T study group is currently focusing on defining the topology, the reach objectives, the cabling requirements and the power consumption of the next generation physical layer interface (PHY).

Let us start by looking at the evolution of the 10GBase-T standard published almost six years ago. Today, 10GBase-T represents about 25% of the switch-to-server market. The main factors that slowed the adoption in the market were the relatively high cost and power consumption of the PHYs compared to 1000Base-T. The first generation 10G Base-T PHYs consumed about 12 watts of power.

Current generation 10GBase-T PHYs, using today’s chip technology, consume considerably less power, between 1,5 to 4 watts depending on the length of the channel. They also take up less space and are more economical. All these advancements are leading to an accelerated deployment of 10GBase-T in the data centre, particularly with the introduction of LAN-on-motherboard (LoM) chips in 2012.

Having learned the lesson from the evolution of 10GBase-T technology, low power consumption is one of the most important considerations for the next generation 40GBase-T PHY. A contribution by Will Bliss of Broadcom is illuminating in this respect. Entitled ‘A Simple Model of Relative Power vs. Reach,’ it shows that the relative power consumption for 40 Gb/s with respect to 10GBase-T is about the same for a reach of 22 metres, about two times more for a reach of 34 metres and four times more for a reach of 46 metres. Every 12 metre increase in reach approximately doubles the power consumption.

In another presentation, Scott Kipp, also of Broadcom, noted that the power consumption can be related to the product of length times the bandwidth. For example, the power consumption of 10G at 100 metres is roughly the same as 40G at 25 metres. The relative power consumption for 40G at 20 metres is approximately 0,8. The relative power consumption for 40G at 10 metres is approximately 0,4. Shorter distances result in considerably less power consumption. The same presentation by Kipp showed that for an ‘end of row topology’ a switch rack at the end of a row can support up to three server racks for a cable distance of 10 metres and 18 server racks for a cable distance of 20 metres. Using a server density of 40 servers/rack, 18 server racks can accommodate 720 servers.

For a ‘middle of row’ topology, with the switch rack located in the middle of a row, a switch rack can support up to 36 server racks or 1440 servers. When a ‘middle of row’ switch rack also supports servers in adjacent aisles, 25 additional racks in each adjacent aisle can be accommodated, for a total of 50 server racks, or 1000 additional servers when using a server density of 40 servers/rack. All this means that with a suitable data centre topology, thousands of high density, rack mounted servers can be supported with a 20 metre link to a modular switch.

Another important consideration in the development of the next-generation Base-T Ethernet standard is the ability to interoperate with legacy slower-speed Ethernet technologies through the function of auto-negotiation.

Compatibility, for auto-negotiation, is facilitated by the use of the 8-pin modular (RJ-45) connector that is currently defined for lower speed Ethernet applications. TIA 42.7 subcommittee is currently developing a Category 8 cabling standard that includes the 8-pin modular connector and 4-pair balanced twisted pair cable that are specified to 2 GHz, which is four times the bandwidth for existing Category 6A cabling.

There was also a joint presentation from Belden, CommScope, Intertek and Fluke Networks that demonstrated the technical feasibility of a cabling system using prototype, Category 8, RJ-45 connectors and prototype Category 8 balanced twisted-pair cables from two different vendors for a short reach (5 m) and long reach (40 m) permanent link configuration. The testing was performed at Intertek, an independent third-party test laboratory, and showed that it is feasible to make components that meet the proposed requirements in the draft Category 8 standard.

What is the main take away from this meeting? After consideration of all the discussion and associated contributions on topology, power consumption and reach, the NGBase-T Study group agreed to the following motions with greater than 75% support, 1) to focus on presentations regarding reach objective in the range of 20 metres to 30 metres, 2) to adopt a 2-connector channel model as an objective.

The above column originally appeared in Cabling Networking Systems, a magazine based in Toronto, Canada. The information presented is the author’s view and is not official TIA correspondence.

For more information contact Greg Pokroy, Jaycor International, +27 (0)21 447 4247, [email protected], www.jaycor.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Hybrid connectors for distributed automation
Beckhoff Automation Enclosures, Cabling & Connectors
Beckhoff’s ECP and ENP connector series combine power with signal and data communication by means of One Cable Automation (OCA) and thus significantly reduce cabling work.

Read more...
Space-saving I/O module for control cabinets
ifm - South Africa Enclosures, Cabling & Connectors
The IO-Link I/O module from ifm simplifies integration of sensors and actuators with conventional wiring in the control cabinet as well as in field applications with low IP protection class requirements.

Read more...
Rittal’s flat-pack enclosure solution
Rittal Enclosures, Cabling & Connectors
The launch of Rittal’s FR IT flat-pack enclosure earlier this year marked a milestone for the company, introducing the local market to a high-capacity, top-tier IT enclosure in a convenient and cost-effective flat-pack format for the first time.

Read more...
The future of industrial connectivity
LAPP Southern Africa Enclosures, Cabling & Connectors
Designed to meet the demands of modern industry, the EPIC DATA RJ45 connector from LAPP delivers a combination of durability, performance and versatility suited to demanding industrial environments.

Read more...
Hybrid connectors for distributed automation
Beckhoff Automation Enclosures, Cabling & Connectors
Beckhoff’s ECP and ENP connector series combine power with signal and data communication by means of One Cable Automation (OCA) and thus significantly reduce cabling work.

Read more...
Power distribution reinvented
Rittal Enclosures, Cabling & Connectors
Rittal has developed the RiLineX, a modular busbar system that redefines how power is distributed inside electrical enclosures.

Read more...
Flexible, lightweight disc couplings for advance
Bearing Man Group t/a BMG Enclosures, Cabling & Connectors
BMG has expanded its extensive portfolio of quality branded couplings with the introduction of the ESCODISC FIL series, a new generation of flexible, lightweight disc couplings.

Read more...
Bayonet connectors with extreme shock and vibration resistance
Enclosures, Cabling & Connectors
ITT Cannon’s versatile and extremely reliable series of CA bayonet connectors are available through Powell Electronics, a specialist in connectors for mission critical applications including defence, aerospace and industrial.

Read more...
High temperature threaded line vacs
Enclosures, Cabling & Connectors
EXAIR’s 3/8 NPT high temperature threaded line vacs convert hose, tube or pipe into a powerful in-line conveying system suitable for use with high temperature materials or in areas of high heat up to 482°C.

Read more...
Understanding flexible multi-conductor cables for industrial applications
Enclosures, Cabling & Connectors
This article provides a brief overview of the cabling requirements of industrial ap-plications. It then introduces examples of super-flexible, continuous-flex cables and shows how their material and specialised construction enables designers to meet these specifications.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved