Preparing for the 40 Gb/s migration

June 2013 Enclosures, Cabling & Connectors

For this article, I would like to report on the ongoing work and direction of the Next Generation Base-T Study Group in IEEE 802.3. What is driving the development of the next generation of Ethernet Standard over twisted pair copper cabling? Answer, the need for higher speed switch-to-server connections.

Recent trends indicate that a large majority of these network connections will be at 10 Gbps by 2015 and will be migrating to 40 Gbps starting in 2015. The NGBase-T study group is currently focusing on defining the topology, the reach objectives, the cabling requirements and the power consumption of the next generation physical layer interface (PHY).

Let us start by looking at the evolution of the 10GBase-T standard published almost six years ago. Today, 10GBase-T represents about 25% of the switch-to-server market. The main factors that slowed the adoption in the market were the relatively high cost and power consumption of the PHYs compared to 1000Base-T. The first generation 10G Base-T PHYs consumed about 12 watts of power.

Current generation 10GBase-T PHYs, using today’s chip technology, consume considerably less power, between 1,5 to 4 watts depending on the length of the channel. They also take up less space and are more economical. All these advancements are leading to an accelerated deployment of 10GBase-T in the data centre, particularly with the introduction of LAN-on-motherboard (LoM) chips in 2012.

Having learned the lesson from the evolution of 10GBase-T technology, low power consumption is one of the most important considerations for the next generation 40GBase-T PHY. A contribution by Will Bliss of Broadcom is illuminating in this respect. Entitled ‘A Simple Model of Relative Power vs. Reach,’ it shows that the relative power consumption for 40 Gb/s with respect to 10GBase-T is about the same for a reach of 22 metres, about two times more for a reach of 34 metres and four times more for a reach of 46 metres. Every 12 metre increase in reach approximately doubles the power consumption.

In another presentation, Scott Kipp, also of Broadcom, noted that the power consumption can be related to the product of length times the bandwidth. For example, the power consumption of 10G at 100 metres is roughly the same as 40G at 25 metres. The relative power consumption for 40G at 20 metres is approximately 0,8. The relative power consumption for 40G at 10 metres is approximately 0,4. Shorter distances result in considerably less power consumption. The same presentation by Kipp showed that for an ‘end of row topology’ a switch rack at the end of a row can support up to three server racks for a cable distance of 10 metres and 18 server racks for a cable distance of 20 metres. Using a server density of 40 servers/rack, 18 server racks can accommodate 720 servers.

For a ‘middle of row’ topology, with the switch rack located in the middle of a row, a switch rack can support up to 36 server racks or 1440 servers. When a ‘middle of row’ switch rack also supports servers in adjacent aisles, 25 additional racks in each adjacent aisle can be accommodated, for a total of 50 server racks, or 1000 additional servers when using a server density of 40 servers/rack. All this means that with a suitable data centre topology, thousands of high density, rack mounted servers can be supported with a 20 metre link to a modular switch.

Another important consideration in the development of the next-generation Base-T Ethernet standard is the ability to interoperate with legacy slower-speed Ethernet technologies through the function of auto-negotiation.

Compatibility, for auto-negotiation, is facilitated by the use of the 8-pin modular (RJ-45) connector that is currently defined for lower speed Ethernet applications. TIA 42.7 subcommittee is currently developing a Category 8 cabling standard that includes the 8-pin modular connector and 4-pair balanced twisted pair cable that are specified to 2 GHz, which is four times the bandwidth for existing Category 6A cabling.

There was also a joint presentation from Belden, CommScope, Intertek and Fluke Networks that demonstrated the technical feasibility of a cabling system using prototype, Category 8, RJ-45 connectors and prototype Category 8 balanced twisted-pair cables from two different vendors for a short reach (5 m) and long reach (40 m) permanent link configuration. The testing was performed at Intertek, an independent third-party test laboratory, and showed that it is feasible to make components that meet the proposed requirements in the draft Category 8 standard.

What is the main take away from this meeting? After consideration of all the discussion and associated contributions on topology, power consumption and reach, the NGBase-T Study group agreed to the following motions with greater than 75% support, 1) to focus on presentations regarding reach objective in the range of 20 metres to 30 metres, 2) to adopt a 2-connector channel model as an objective.

The above column originally appeared in Cabling Networking Systems, a magazine based in Toronto, Canada. The information presented is the author’s view and is not official TIA correspondence.

For more information contact Greg Pokroy, Jaycor International, +27 (0)21 447 4247, [email protected], www.jaycor.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

PPS delivers custom drag boxes for coastal mining in Madagascar
Enclosures, Cabling & Connectors
South African electrical enclosure specialist, Power Process Systems has successfully delivered a set of custom-engineered drag boxes for a major titanium mining project in Madagascar.

Read more...
New industrial single-pair Ethernet connectors
Enclosures, Cabling & Connectors
The new Industrial SPE connectors and cable assemblies from KYOCERA AVX offer significant space and weight savings and can also help reduce system complexity and costs, and improve reliability and efficiency.

Read more...
Cable care is critical to machine longevity
Enclosures, Cabling & Connectors
The management of moving cables and hoses in machine building is critical to the operation and longevity of equipment, with modern systems like energy chain cable carriers often replacing conventional systems like cable festoons, reels or free-hanging loops.

Read more...
The advantages of using an adjustable cable gland
Enclosures, Cabling & Connectors
Pratley continues to demonstrate its engineering leadership with its innovative adjustable cable gland, designed to significantly reduce maintenance and labour costs across a wide range of industrial applications.

Read more...
Revolutionising plant operations with ETHERLINE GUARD
LAPP Southern Africa Enclosures, Cabling & Connectors
Ethernet cables often suffer from wear and tear, environmental factors or accidental damage, leading to unexpected failures. LAPP Group understands these pain points and is proud to introduce the ETHERLINE GUARD PM03T/PM02TWA, an innovative solution to keep your operations running smoothly.

Read more...
Harnessing solutions for industrial applications
Enclosures, Cabling & Connectors
Cable technology and harnessing solutions specialist, Lapp offers an advanced range of customised wire harnessing and cable assembly solutions.

Read more...
Pluggable system solution helps tackle skills shortages and addresses DC power supply needs
Beckhoff Automation Enclosures, Cabling & Connectors
As a replacement for the conventional control cabinet, the MX-System from Beckhoff is a uniform modular automation system that can be used to completely replace traditional control cabinets with function modules in many applications.

Read more...
Competitive advantage for Lapp customers with bespoke solutions
Enclosures, Cabling & Connectors
Lapp’s bespoke manufacturing service delivers unique and original designs to customers, leading to technological and competitive advantage.

Read more...
USB-C connector with ratchet locking system for maximum vibration and shock resistance
Enclosures, Cabling & Connectors
Fischer Connectors has brought its world-renowned Swiss engineering expertise to the universal USB-C standard.The Fischer UltiMate Series, the company´s flagship range for harsh environments, now includes a pre-cabled USB-C connector equipped with Fischer Connectors´ new Ratchet Locking System.

Read more...
Seamless connectivity and interoperability of soldiers’ digital equipment
Enclosures, Cabling & Connectors
Fischer Connectors’ Swiss-engineered MIL-SPEC solution features an expanded portfolio of cables and connectors offering a competitive solution in line with the US Army’s Next Generation Hub (NGH) specifications.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved