Fieldbus & Industrial Networking


Diesel generator monitoring systems

Technews Industry Guide: Maintenance, Reliability & Asset Optimisation 2017 Fieldbus & Industrial Networking

System Integrators (SIs) in the heavy-duty vehicle industry agree that their biggest headache is integrating a diesel generator (the combination of a die-sel engine and electric generator) with the large variety of diesel generator monitoring systems (DGMSs) or programmable logic controllers (PLCs). The job is complicated by the many different communication protocols and interfaces used in the industry, arduous pre-configuration methods, and time-consuming troubleshooting.

The emergence of DGMSs

The monitoring of diesel generators has taken on a much more important role in power generation as more emphasis is placed on Overall Equipment Efficiency (OEE). A continuous power supply as well as high-voltage power is required to maintain nonstop operations in mission-critical industries, such as backup power systems, automatic transfer switches (ATSs), heavy-duty trucks, and tractors. Diesel generators have been widely adopted as power generation instruments because they are deployed easily at any field site or industrial plant, and they don’t take up a lot of space. Their implementation costs are also very low.

A DGMS monitors the status of a diesel engine or a diesel generator, including voltage, amperage, RMS, PR, RMO, and other parameters. It also sets off an alarm in the case of an engine failure. Additional monitoring functions pertain to the generator’s fuel status, including fuel pressure and fuel consumption (especially to alert the control room when thefts occur).

A Global Positioning System (GPS) located at the field site transmits the data to a control room. Furthermore, some diesel generator plants also use an auto-on/off mechanism preconfigured by an engineer. When the engine switches on or off, the engineer is notified.

It should also be mentioned that at some plants, PLC systems are also used to control and monitor diesel generators. Unlike DGMSs, they are mainly used to control and monitor diesel generators according to the logic control program configured by an engineer.

Getting it right

When dealing with so many different types of DGMSs or PLCs – which vary from application to application, country to country, and design to design – it is necessary to find the right protocol gateway to achieve integration. Most diesel generators run the CAN-SAE J1939 protocol, which enables communication and diagnostics among vehicle components, diesel generators, and compression engines, and is suitable for the heavy-duty truck industry and backup power systems at field sites. On the other hand, DGMSs and PLCs employ a number of different protocols. Some DGMSs or PLCs use Modbus, whereas others use Ethernet/IP or Profibus; it all depends on the vendor, the country, and the industry.

Hence, a protocol conversion gateway is required to connect the diesel generator to a DGMS or PLC, functioning as a communication bridge between J1939 and Modbus, EtherNet/IP, or other protocols. However, simply acquiring and setting up a protocol gateway is easier said than done. Installation and maintenance turn out to be quite tricky for field engineers when bridging a diesel generator with a DGMS or PLC via a protocol gateway.

In many cases, SIs have to buy different gateways from different vendors, each with its own configuration methodology. Of course, the most obvious solution is to find a provider that offers various models catering to the large variety of DGMS/PLC systems out there. The snag, however, is that SIs still have to buy many different kinds of models to get the job done – and a big purchase requires a big budget. The reason behind the large number of required models is that, for example, many DGMSs and PLCs support up to four different protocols, requiring SIs to get four different models, each supporting one of the four supported protocols, to bridge communication between diesel generators and DMGSs or PLCs.

All-in-one design

The trend among protocol gateway providers is to design gateways that have identical hardware in order to minimise I/O interfaces, thereby cutting costs on hardware spending. Moreover, the various configuration interfaces, i.e., the software functions, have been consolidated into one software suite, eliminating the need for users to download a lot of different firmware files to execute different protocol conversions. A comprehensive software program benefits users in that they only have to work with one type of configuration interface, and no longer need to familiarise themselves with many different configuration interfaces. Users simply have to choose any of the two required protocols from a list provided via a web console for the intended protocol conversion to be carried out.

Bridging diesel generators and DGMSs or PLCs

A number of factors need to be considered before SIs set their sights on a gateway that best fits their purposes. These factors are discussed in more detail below:

1. Setting J1939 manually

A diesel generator might have a lot of J1939 Parameter Group Number (PGN) commands, which, depending on the diesel generator, the engineer may need to key in manually. This is a time-consuming operation prone to human error. A well-designed gateway should support a command-learning function, allowing it to learn all the J1939 PGN input commands in only a few steps. Even if many J1939-supported devices are deployed on the same CAN bus, the gateway will be able to recognise each J1939-supported device, with its J1939 commands, individually on the same CAN bus. The operational efficiency will be much higher, and the total cost of ownership will be lower.

2. A web console for easy configuration

It is safe to say that most field engineers are knowledgeable about J1939 and know how to set it up, and they may also know enough about DGMSs and PLCs. However, they may not be as familiar with protocol gateways, which are not always easy to set up. The easiest way to set up a gateway is through a web console, making the installation of an additional vendor-provided utility unnecessary. All that is required is a laptop with an Ethernet cable and a web browser to log in to the web page of the protocol gateway.

3. A shrapnel-type terminal block

A shrapnel-type terminal block is preferred over a screw-type terminal block since cables tend to come loose in the latter after a long period of use, often due to vibrations. Furthermore, an extension cable slot for a CAN (control area network) bus is also required to allow CAN devices to connect in a daisy-chain topology. For this reason, a shrapnel-type terminal block with separate inbound and outbound slots is required as it is more suitable for daisy-chain wiring.

4. A built-in SD card design

Many SIs can vouch for just how time-consuming it is to configure all the gateways at a site, since the configuration process usually involves repeating the same configuration method for each gateway. A gateway with a built-in SD card slot can save SIs time and frustration in this regard. After setting up the first gateway, the configuration instructions can be automatically stored on the SD card, which can then be used to complete the configuration of the rest of the gateways. The engineer only needs to insert the SD card and turn on the gateway. All the configurations will be set in the new gateway automatically, freeing up valuable time for engineers.

5. Easy troubleshooting

Field engineers are often unfamiliar with protocol gateways, which to them are essentially third-party devices. They tend to struggle to connect the gateway to the DGMS/PLC correctly, since they do not know enough about the communication protocols. A built-in traffic monitor function monitors J1939 protocol traffic, permitting users to monitor the status of the connected CAN devices, including error count, packet count, and bus-offline. The traffic monitor function can also be used to troubleshoot CAN-supported devices. Furthermore, the diagnostic tool helps users check CAN device settings and indicates the availability of CAN devices by reading the J1939 network address.

Moxa solutions

Moxa’s MGate 5118 series does away with the need to purchase, deploy, and set up multiple devices to perform various protocol conversions. In a single device, it supports the protocol conversions for J1939 to Modbus RTU/ASCII, Modbus TCP, Profinet, or EtherNet/IP, which are the mainstream protocols used in the field. Furthermore, the Moxa MGate 5118 provides an innovative command-learning mechanism. All you need to do to set a J1939 command is click on the AutoLearn button through a web console; the user interface will show you how many J1939 devices are connected to a daisy-chain CAN bus. It also displays the J1939 input commands of each J1939 device, and reduces human error by cutting back on the time spent manually keying in all the J1939 commands.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

EtherCAT interoperability removes industrial networking barriers
Fieldbus & Industrial Networking
Selecting the right communication technology is one of the most important decisions engineers make, and interoperability helps with that decision. Key development tools and standards ensure interoperability among many EtherCAT devices and manufacturers.

Read more...
Condition monitoring to go
Turck Banner Southern Africa Fieldbus & Industrial Networking
Anyone who wants to efficiently monitor the climate in control cabinets will find a comprehensive range of control cabinet monitors for the DIN rail in Turck Banner’s cabinet condition monitoring family.

Read more...
Innovative separation of recyclable materials
Beckhoff Automation Fieldbus & Industrial Networking
A plant built by Belgian specialist machine builder, Absolem Engineering features an innovative process for separating recyclable materials. Using PC-based control from Beckhoff, a major problem has been elegantly solved - the generation of different signal sequences for the exact synchronisation of different camera systems.

Read more...
Enhancing AI-powered object detection and recognition capabilities
Vepac Electronics Fieldbus & Industrial Networking
Innodisk has announced its cooperation with Advantech, a global leader in AIoT and edge computing. This collaboration leverages Innodisk’s customisable MIPI camera modules and Advantech’s Intel x86-based AFE-R360 solution to enhance AI-powered object detection and recognition capabilities, expanding visual applications for autonomous mobile robots in smart factories and warehouses.

Read more...
Rugged, agile and scalable boards
Vepac Electronics Fieldbus & Industrial Networking
Embedded computing pioneer, AAEON has launched the PICO-ASL4 and GENE-ASL6, both featuring the new Intel Atom x7000RE Processor Series for the edge.

Read more...
Connecting every transport node
RJ Connect Editor's Choice Data Acquisition & Telemetry
Stockholm's bus system strategically links urban mainline, suburban mainline, non-mainline routes, community service buses and night buses. To acquire and process data from multiple sources and analyse onboard information on their moving buses, Transdev sought a dependable and powerful onboard computer. It teamed up with CatAB, Moxa’s local representative, known for delivering top-notch industrial data communication boards and equipment since 1988.

Read more...
Rugged gateway board with open-source flexibility
Vepac Electronics Fieldbus & Industrial Networking
The SRG-CM4 from Vepac brings all the open-source flexibility of the Raspberry Pi OS and ecosystem to AAEON’s signature rugged, durable gateway design to create a truly industry-ready modular system.

Read more...
New safety I/O modules for functional safety in highly automated operations
Fieldbus & Industrial Networking
Belden has expanded the Lumberg Automation LioN family with its new LioN-Safety I/O Modules. Designed to support functional safety efforts in industrial operations, the modules streamline the transmission of data over existing networks.

Read more...
IO-Link master for the automation and IT world
ifm - South Africa Fieldbus & Industrial Networking
The decentralised IO-Link master modules from ifm serve as a gateway between intelligent IO-Link sensors and the fieldbus. Important information on the intelligent sensors can also be simultaneously sent.

Read more...
Condition monitoring with IO-Link rotary encoders
Pepperl+Fuchs Fieldbus & Industrial Networking
Whether in the materials handling industry, in packaging machines or in wind turbines, sensors with an IO-Link interface are increasingly being used to pave the way to Industry 4.0. Pepperl+Fuchs was one of the first manufacturers to launch an absolute rotary encoder with IO-Link interface, that was available in numerous variants and with a wide range of setting parameters.

Read more...