Sensors & Transducers


Humidity measurement in poultry farms

August 2017 Sensors & Transducers

Incubation

Eggs are kept in the incubator for a total of 18 days. There are two schools of thought on the correct humidity level to use during this stage. The most popular condition for incubating the eggs is 53% RH @ 37°C. Towards the end of the incubation period, the eggs will start to release CO2, which builds up in the incubator. Valves open to vent this excess and keep the CO2 close to atmospheric levels, which has the side effect of venting water vapour and reducing the humidity level inside, therefore humidifiers are used to compensate for this and keep the level around the required 53%.

Some customers see better uniformity of chicks when they are incubated in a higher humidity initially – 60% or higher in some instances (still at 37°C). They still vent the excess CO2 towards the end of the incubation cycle, but do not replace the water vapour lost at this stage.

If the egg tray is not completely full, then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

The measurement in this environment is fairly clean and after 18 days the eggs are moved to another room. Cleaning methods will vary from site to site, but typically are less invasive. The sensors here typically will have a longer lifetime than those in other areas of the farm.

Hatching

Following the 18 days of incubation, the eggs are moved to the hatcher, where they spend a total of three days. This cycle also begins with a condition of 53% RH @ 37°C. As soon as the chicks begin to hatch, the humidity level naturally increases, up to around 80%. This higher humidity actually assists the other chicks by making the shells slightly softer, allowing them to hatch more easily.

As the chicks hatch, CO2 levels also increase, so ventilation and humidification starts. Once all the chicks are hatched, humidity will be maintained around 60%.

As in the incubator, if the egg tray is not completely full then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

This is a more demanding measurement as the hatching is a messy process. After the chicks are removed, the room will be decontaminated by pressure-washing with a mixture of water and disinfectant. It is this stage which is particularly damaging to the sensor, which should ideally be removed, or at least covered up while this cleaning process is taking place.

Adult chickens

Normal body temperature for chickens is 41,5°C, however this will fluctuate depending on environmental temperature. Maintaining a constant body temperature is not a problem when air temperature is at least 10-15 degrees less than body temperature, but air movement is critical. A bird can only give off heat to its environment if the temperature of that environment is cooler than the bird. If heat produced by the birds is not moved away from them and out of the poultry house quickly, it will be more difficult for them to avoid heat stress.

The ambient temperature should be maintained at <around25°C to avoid stressing the chickens, but more importantly, the environmental temperature should be kept as stable as possible. Fluctuations in the temperature, especially in combination with high relative humidity, will be more stressful to the birds than a high ambient temperature alone.

Measurement

This is the toughest measurement of the three as any sensors installed into the living environment or on the air outlets will experience drift over time, due to the NH3 content in the air. There is also a significant amount of dust, which can cause premature failure on sensors with inadequate filtration.

By far the best location for controlling this environment is on the fresh air inlet.

Cleaning will also periodically take place in this environment, and the same precautions should be followed as in the hatchery, the sensors should be either removed or covered to prevent irreversible damage.

Michell’s HydroSmart HS3 probe

The probe is proven to be a suitable product for withstanding the conditions described above, if the following precautions are adhered to:

• Probes should be mounted in a vertical orientation.

• Probes should always be covered, or ideally removed completely, during decontamination/cleaning cycles.

• Probes should never be cleaned with any kind of solvent, detergent or pressurised water, they should just be wiped down with a damp cloth.

For more information contact Instrotech, +27 (0)10 595 1831, [email protected], www.instrotech.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

The smallest most powerful infrared sensor in the world
Sensors & Transducers
The superior performance and robustness of Telco’s infrared sensors ensures that there are no limits to any mining and industrial applications.

Read more...
Easy parameter setting of vision sensors
ifm - South Africa Sensors & Transducers
Contour verification and object inspection are two of the most important functionalities in industrial imaging. With the new O2D5xx series, ifm now offers a solution that perfectly masters both functionalities

Read more...
New range of vision units
Beckhoff Automation Sensors & Transducers
Beckhoff has added four new vision units to its VUI2000 series. They integrate a camera, illumination and liquid lens technology for simplified installation.

Read more...
Condition monitoring sensor
Sensors & Transducers
The Balluff BCM Gen2 Condition Monitoring Sensor is an advanced IIoT-ready device designed for real-time machine health monitoring.

Read more...
Inductive IO-Link sensors
Turck Banner Southern Africa Sensors & Transducers
Turck Banner is expanding its sensor range, with inductive measuring sensors with IO-Link and an analogue output for flush and non-flush mounting.

Read more...
Value of PDS grows with data and sensing technology
Sensors & Transducers
Rapidly developing technology is constantly being harnessed by proximity detection systems (PDS) to deliver steadily improved functionality to customers. Booyco Electronics sees improved PDS solutions being developed, such as the combination of multiple different sensing technologies into a single fully integrated solution.

Read more...
Pulp fiction or pulp precision?
VEGA Controls SA Sensors & Transducers
The density of fruit concentrate has a direct impact on the flavour, texture and overall quality of the final product. The VEGA Minitrac 31, VEGASOURCE 31, and the KV 31 mounting bracket present a failproof solution that effectively addresses the technical complexities associated with high temperature, viscosity and fouling.

Read more...
Telco sensors in the pulp and paper industry
Gail Norton Instrumentation Sensors & Transducers
The pulp and paper industry poses a major problem for most photoelectric sensors. The high level of contamination in these dusty, dirty and grimy environments makes it impossible for most competing sensors to operate and sense reliably and efficiently.

Read more...
Vibration monitoring with IO-Link
ifm - South Africa Sensors & Transducers
Machine vibrations are important indicators when it comes to assessing the current condition of a machine. fm’s new and smart IO-Link vibration sensor helps to implement a simple and scalable condition monitoring approach using only a single device.

Read more...
Unique industrial asset monitoring solution
WIKA Instruments Sensors & Transducers
WIKA WikaPredict offers a unique industrial asset monitoring solution, combining advanced sensors and artificial intelligence. As a leader in predictive maintenance, it helps clients enhance operational performance and increased efficiency.

Read more...