Electrical Power & Protection


Preventing false alarms caused by lightning strikes and surges

February 2015 Electrical Power & Protection

The function of emergency alarm systems, albeit fire or burglar, is to produce an alarm in the event of danger and to remain passive when there is none. The malfunction of these systems, either no alarm sounding if there is danger or an alarm sounding unnecessarily, is not just a nuisance; it can also be dangerous and can result in expensive call-out fees.

False alarms have the following consequences:

• Security personnel start ignoring the alarm messages.

• Neighbours are disturbed by acoustic alarms.

• Emergency staff is unnecessarily called out.

• The triggering of fire extinguishing systems can cause interruption of operations.

All these factors cause unnecessary costs and can be prevented if possible causes of false alarms are recognised at an early design stage and are eliminated by taking suitable preventive measures. Lightning strikes are one such cause, and given the profusion of summer storms in South Africa, this is a real threat. And with many businesses closing over the December holiday, ask yourself: do you want to be called back if your property experiences a false alarm? Coordinated lightning and surge protection prevents false alarms or the destruction by atmospheric discharges or switching over voltages and increases the availability of the systems.

Many of today’s emergency alarm systems have an increased immunity to transients on the primary lines, secondary lines and mains voltage cables according to IEC 61000-4-5. Nevertheless, only external and internal lightning protection measures provide comprehensive protection against damage resulting from lightning strikes and surges.

Monitoring principles

Different monitoring principles are used for emergency alarm systems:

• Pulse polling technology: Information from the sensor which has triggered the alarm is digitally transmitted. This allows the identification of the sensor and its exact location.

• DC circuit technology: According to the closed circuit principle, every alarm line is permanently monitored. If a sensor in a line is triggered, the line is interrupted and an alarm is produced in the alarm panel. However, only the alarm line, but not the individual sensor can be identified.

Irrespective of the monitoring principle used, all cables extending between the different areas of the emergency alarm system must be integrated in the lightning and surge protection concept of the overall system.

Recommended protection

Dehn’s Blitzductor XT, type BXT ML2 BE, must be installed to protect two-wire alarm lines and connect the earth drain wire by means of an EMC spring terminal. For cables with more than two wires, a four-wire version, BXT ML4 BE, is available. Surge protective devices are selected according to the voltage of the alarm lines, which is typically between 12 and 48 V. The low internal resistance is also a clear advantage of Blitzductor arresters since the maximum resistances of the alarm lines must not be exceeded. For the outputs of the alarm panels (acoustic and visual) it must be ensured that the nominal current of the surge protective devices is not exceeded.

For more information contact Alexis Barwise, Dehn Protection South Africa, +27 (0)11 704 1487, [email protected], www.dehn-africa.com





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Schneider Electric accelerates adoption of SF6-free switchgear
Schneider Electric South Africa Electrical Power & Protection
Schneider Electric is driving the transition to sustainable medium-voltage solutions across East Africa with its award-winning SM AirSeT pure-air switchgear.

Read more...
Critical power distribution for modern infrastructure
Electrical Power & Protection
Legrand has expanded its critical power portfolio with integrated solutions designed for reliable, efficient, safe and flexible power distribution in many applications, including data centres and industrial sites.

Read more...
How to use a voltage tester
Comtest Electrical Power & Protection
Voltage testers are valuable tools for professionals who work with electrical systems.This application note will guide you on how to use a voltage tester effectively, and which Fluke voltage testers can assist in a variety of settings.

Read more...
Film capacitors for noise suppression
Electrical Power & Protection
Würth Elektronik has expanded its portfolio of components for the mains input. The new series of WCAP-FTY2 film capacitors is optimised for use in noise suppression and complies with X1 or Y2 safety classes in accordance with IEC 60384-14.

Read more...
Emissions pressures are not just hot air
Electrical Power & Protection
Dennis Williams, commercial director of AES says that the South African government aims to push towards global standards in emissions, but it might be difficult for our industries to carry the financial burden. This is where AES fits in.

Read more...
ABB achieves zero operational emissions
ABB South Africa Electrical Power & Protection
ABB’s factory in Oiartzun, Spain, has reached a major sustainability milestone.

Read more...
Supporting the AI boom with power architecture
Electrical Power & Protection
Hitachi Energy is supporting the 800 VDC power architecture announced by Nvidia, by developing a cleaner, more efficient way to power the next generation of AI infrastructure.

Read more...
Terminal blocks with Push-X technology for wiring from 0,34 mm2
Phoenix Contact Electrical Power & Protection
The Push-X product range is growing. With the new XT 1,5 terminal blocks, Phoenix Contact is extending the series to include versions for conductor cross-sections from 0,34 to 2,5 mm2.

Read more...
Energy cannot be destroyed, it can only be transferred
Schneider Electric South Africa Electrical Power & Protection
Industry produces significant amounts of waste. Unfortunately, a lot of this waste is simply disposed of, usually impacting the environment. What if these byproducts could be transformed into a source of energy?

Read more...
Dual head safety pull switches with expanded cable span
Electrical Power & Protection
Referro Systems has added the latest Dual Head range of Allen-Bradley’s safety pull switches to its portfolio. It is ideal for protecting long stretches of equipment where quick access to a safety pull switch and emergency stop is vital.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved