Pneumatics & Hydraulics


Myths and truths: compressor efficiency and variable speed drives

October 2007 Pneumatics & Hydraulics

The myth: Variable speed drive compressors are more energy-efficient than traditional compressors that employ on/off control.

Analysis: With many industrial facilities often operating around the clock, plant-wide efficiency is paramount. The compressed air requirements on any given industrial site can be numerous and varied. Often, each application requires varying quantities of compressed air at different pressures, and at intermittent times. The resulting fluctuation in compressor load profile can complicate the task of selecting an appropriate compressor system.

In recent years, this quest for energy efficiency has seen an increase in the use of variable speed drive (VSD) compressors. It is often - and incorrectly - assumed that a VSD will always provide a more energy-efficient means of controlling the output of an air compressor than that of an on/off motor. This misconception is born from the popular belief that a variable speed rotary screw air end displays the same performance characteristics as a variable speed fan. There is, however, a fundamental difference between the two - the efficiency of a rotary screw air end is affected by changes in the speed of the apex of the rotary screw (tip), while the efficiency of a rotating fan blade remains essentially constant, regardless of the rotational speed of the fan (see Figure 1).

Figure 1. The efficiency of a rotary screw air end is affected by changes in the speed of the apex of the rotary screw (tip), while the efficiency of a rotating fan blade remains essentially constant, regardless of the rotational speed of the fan
Figure 1. The efficiency of a rotary screw air end is affected by changes in the speed of the apex of the rotary screw (tip), while the efficiency of a rotating fan blade remains essentially constant, regardless of the rotational speed of the fan

This difference stands to reason, given that the rotary screw air end is a far more complex device than a simple fan. A rotary screw air end transforms the volume, temperature and pressure of incoming air, whereas a fan merely moves the air from one side of the fan blade to the other.

VSD compressors, by design, have an optimum tip speed 'envelope' within which they operate most efficiently. The optimum efficiency 'envelope' is usually bound by tip speeds of 20 m/s (at the low end) and 40 m/s (at the high end). A tip speed of less than 20 m/s results in air escaping back through the tip, while tip speeds greater than 40 m/s creates turbulent and inefficient compression.

Unfortunately, VSD compressors are designed to span the entire tip speed range corresponding to 0 to 100% compressor load. As a result, VSD compressors cannot operate within this optimum tip speed 'envelope' across the entire capacity range of the compressor. Manufacturers of VSD compressors predominantly size the air end to operate with an optimum tip speed corresponding to 70% load. When compressor loads reach above or below 85%, the tip speed is in turn adjusted above or below the optimum, and the VSD compressor's efficiency drops away.

As a result, compressors employing VSDs are more efficient than conventional on/off motor-driven compressors through approximately 50% of their capacity range - outside this '50%' envelope they are far less efficient. The manufacturer determines where this '50%' envelope lies. If the compressed air load regularly occurs outside this range, then other compressor options would be best suited to the application in place of a VSD compressor.

A variable output compressor (VOC) represents an ideal solution to maximising the efficiency of compressed air usage on the plant floor. The VOC is able to address changes in compressed air demand without changing the tip speed, making it one of the most energy-efficient compressed air solutions available. By controlling the delivery of air to the rotary screw air-end, the effective rotor length and compression volume is modified, enabling the delivery of compressed air at the selected capacity and pressure (see Figure 2). The VOC operates at an optimum tip speed across the entire load range (0-100%) and does not change throughout the output capacity range.

Figure 2
Figure 2

Conclusion: Before spending capital on a VSD compressor, careful analysis of the compressed air requirements of the application is crucial. It may cost more to run a VSD compressor. VSD compressors are only a more efficient compressor option in a limited number of applications. Conventional on/off load compressors are often still a more cost-effective solution.

A rotary screw air end has an optimum tip speed envelope that can be breached by a VSD. When compressor loads frequently reach levels that demand rotor speeds outside of the optimum tip speed envelop efficiency decreases and energy and money is wasted.

The ‘Compressor Myths and Truths’ series is supplied by Champion Compressors, an Australian-based designer and manufacturer of industrial rotary screw air compressors especially designed for harsh environments.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

How laser cladding delivers 33% more life and maximum ROI in hydraulic cylinders
Pneumatics & Hydraulics
By utilising advanced laser cladding, Honingcraft can help clients achieve a 33% longer life from their components, ensuring they secure the maximum return on their investment.

Read more...
Identifying signs of hydraulic cylinder wear and tear
CT Hydraulics (Nqoba) Pneumatics & Hydraulics
Recognising the early warning signs of hydraulic cylinder degradation is crucial for preventing costly downtime, ensuring operator safety and maximising the lifespan of your hydraulic systems.

Read more...
Integrated Air Solutions opens Pinetown branch
Pneumatics & Hydraulics
Integrated Air Solutions has opened a branch in Pinetown, bringing world-class diesel and electric air compressor services closer to customers in KwaZulu-Natal.

Read more...
Cartridge-style flowmeter
Axiom Hydraulics Pneumatics & Hydraulics
Sun’s new cartridge-style flowmeter QMEH delivers precise, real-time flow measurements for demanding hydraulic applications. Using a custom-built, state-of-the-art sensor, the QMEH accurately detects flow and converts the electrical signal into a proportional flow rate.

Read more...
Robust sensors for pneumatic applications
ifm - South Africa Pneumatics & Hydraulics
The pressure sensors from ifm have a G1/8 process connection, combined with a welded thin-film measuring cell. While offering an unbeatable price/performance ratio, this technology provides for high measuring accuracy in a very compact and robust housing.

Read more...
A guide to common hydraulic system contaminants
CT Hydraulics (Nqoba) Pneumatics & Hydraulics
Every engineer, machine designer and maintenance professional understands that the heart of any reliable hydraulic system is its fluid. But the moment that fluid is compromised, your system’s life expectancy and your peace of mind drop dramatically.

Read more...
Compressed air piping design
Artic Driers International Pneumatics & Hydraulics
When designing a compressed air pipeline, remember that size matters. The internal size of the pipe, along with the pressure and air volume, determine the velocity of the compressed air in the pipeline.

Read more...
Tuning into what your system is telling you
Hydrasales Pneumatics & Hydraulics
Hydraulic presses can run like clockwork, but often it’s the things you don’t see, or hear, that carry the most telling signs of irregular system health.

Read more...
Direct-controlled seat valve
Pneumatics & Hydraulics
A new direct-controlled seat valve enables storage-free, load-tight holding functions in dynamic linear units without an additional control pressure supply, and offers significant advantages over classic, pilot-controlled solutions, particularly in stationary and servo hydraulics.

Read more...
Gauge maintenance for shutdown
SA Gauge Pneumatics & Hydraulics
As the year winds down, many plants across South Africa prepare for the annual shutdown. It’s also the perfect opportunity to give your pressure and temperature gauges the attention they deserve.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved